2007-05-10 16:12:42 
 FAILED FOR FOLLOWING REASONS: VERY IMPORTANT,PLEASE
 RESPOND EACH ITEM OF THE LINE#.
  
 1. PLEASE SHOW ON DRAWINGS ALL STANDARDS NOTES OF CITY
 OF WPB FOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY,
 PARKING, HANDICAP PARKING, PAINTPER CITY CODES
 ETC.YOU CAN GET A CD FROM 100045TH STREET ENG.,, MUST
 MEETALSO ADA,,STANDARDS AND PLEASE SHOW ON THE
 DRAWINGS.
 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE
 DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION
 MUST BE ACCESSIBLE FOR PICKUP TRUCK.
 3. PLEASE SHOW ON DRAWINGS FIRST FLOOR ELEVATION,
 CENTER LINE OF ROAD ELEVATION , SIDEWALK ELEVATION MUST
 MEET FLOOD ZONE OF THAT AREA & FL BLDG CODE.WHAT
 CRITERIA YOU USED IN DETERMINING FIRST FLOOR ELEVATION
 LIKE 5 YEAR,10 YEAR, 25 YEAR, 100 YEAR FLOOD, PLEASE
 SHOW ALL THESE CALCULATIONS,YOU NEED TO USE THE WORST
 CASE TO GET SAFER DESIGN FOR FIRST FLOOR ELEVATION.
 PLEASE SHOW ON THE DRAWINGSTHAT ON FIRST FLOOR
 ELEVATION.
 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT, & GEOTECH
 REPORT AGAIN.
 5.IN YOUR STORM WATER QUALITY CALCULATIONS, WHY YOU DID
 NOT USE THE WORST CASE FOR SAFER DESIGN, 2.5" CRITERIA,
 YOU CALCULATED RETENTION VOLUME 0.45 ACRE-FEET ,
 INSTEAD YOU USED .07 ACRE-FEET. TO DETERMINE THE LENGTH
 OF EXFILTRATION TRENCH,WOULD HAVE BEEN LONGER AND
 SAFER IF YOU USED 0.45 ACRE-FEET.. PLEASE EXPLAIN.
 PLEASE GET A COPY OF THIS CRITERIA FROM SFWMD FOR
 DETAIL CALS & METHODS.
 6. PLEASE PROVIDE ON DRAWINGS THE TOTAL SITE AREA,
 PERVIOUS AREA, GREEN, LAKES, ETC,IMPERVIOUS
 AREA,BUILDING,PARKING LOT,SIDEWALK ETC.
 7. HOW DIDYOU CONNECT TO THE STORM WATER PIPES IN
 YOUR SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER
 PIPES AROUND YOUR SITE SO, WE CANSEE THE BEST STORM
 WATER PIPE TO CONNECT WITH THE STORM WATERFROM ALL
 OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE
 CONTROL STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ?
 8. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT
 ETC., PLANS SHOWING SILT FENCE AROUND THE SITE
 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH
 STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVE
 10. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND
 YOUR SITE FOR STORM WATER DRAIN.
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS.
  
 RASIK CHOKSHI805-6723