Plan Review Notes
Plan Review Notes For Permit 06101122
Permit Number 06101122
Review Stop B
Sequence Number 2
Notes
Date Text
2007-07-09 17:04:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB
 FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
  
 COMMENTS FROM PREVIOUS LIST:
  
 1.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO
 PERMIT PICKUP, FS713.13.
  
 2.)IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY
 PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD.THE PLANS
 MUST BE STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.PLEASE CALL 561-233-5025 FOR MORE
 INFORMATION.
  
 3.)INCLUDE FBC EB IN GOVERNING CODE.DECLARE LEVEL
 OF ALTERATION, FBC EB CHAPTER 3.
  
 4.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER
 OF RECORD, FBC*106.3.3.
  
 2ND REVIEW - THIS MAY BE DONE WITH A SHOP DRAWING
 REVIEW STAMP OR A LETTER.
  
 5.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED
 IN ADDITION TO THE NOAS SUBMITTED, FAC9B72.
 WWW.FLORIDABUILDING.ORG.THE FLORIDA STATE PRODUCT
 APPROVALS PROVIDED ARE EXPIRED; FBC2001 RATHER THAN
 FBC2004.PLEASE PRINT CURRENT APPROVALS.
  
 2001 APPROVALS WERE SUBMITTED FOR PGT PW701, WINDSOR
 DOOR (2004 REQUIRED).NONE PROVIDED FOR THE PGT
 MULLION.
  
 6.)ADDRESSED.
  
 7.)SHOW REQUIRED HEAD CLEARANCE FOR THE ATTIC ACCESS,
 R807.IT DOES NOT APPEAR TO BE COMPLIANT IN THIS
 LOCATION.
  
 2ND REVIEW -IT IS NOT CLEAR HOW THIS WAS ADDRESSED.
  
 8-10.)ADDRESSED.
  
 11.)SHOW DRAINAGE TO COMPLY WITH FBC R401.
  
 12.)DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3.
  
 13.)PROVIDE A SOILS INVESTIGATION REPORT, FBC
 R401.4.
  
 2ND REVIEW - THIS WAS NOT SUBMITTED.THE SOILS REPORT
 SHOULD ALSO ADDRESS THE EXISTING POOL AREA.
  
 14-15.)ADDRESSED.
  
 16.)DOES THE GARAGE DOOR HAVE GLAZING?NOTE THAT
 GLAZING IS AN OPTION ON THE PRODUCT APPROVAL SUBMITTED
 BUT REQUIRES IMPACT PROTECTION.
  
 THIS MAY BE ADDRESSED BY WRITING "NO GLAZING" ON THE
 PRODUCT APPROVAL.IF YOU ARE USING THE GLAZING OPTION,
 IMPACT PROTECTION REQUIRED (WITH PRODUCT APPROVALS AND
 ATTACHED INSTALLATION SCHEDULE COMPLETED).
  
 17.)ADDRESSED.
  
 18.)CHANGES TO THE PLAN MUST BE DONE BY THE DESIGNER
 OF RECORD, CLOUDED, INITIALLED AND DATED.REVISIONS
 WERE DONE ON A1 AND A3 APPARENTLY BY SOMEONE OTHER THAN
 THE ENGINEER.
  
 2ND REVIEW - CHANGES WERE NOT CLOUDED.THIS REQUIRES
 AN ENTIRELY NEW PLAN REVIEW AND WILL CAUSE DELAYS. ALL
 REVISIONS/CHANGES TO THE PLAN ARE TO BE CLOUDED AND
 NUMBERED.
  
 19.)ELEVATIONS ON A1 SHOULD NOTE EXISTING AND
 ADDITION AREAS.
  
 20.)THE ADDING STRAP DETAIL S2 DOES NOT COMPLY WITH
 THE SIMPSON CATALOG.ADDRESS.CHECK ALL CONNECTORS.
  
 21.)SHEET D-2, HIB-91 HAS BEEN REPLACED BY TPI/WTCA
 BCSI 1-03.CHECK ALL REFERENCES.FOR INSTANCE,
 CONCRETE NOTE REFERS TO ACI 544.1R-82.THERE ARE OTHER
 EXPIRED REFERENCES.SEE FBC35.
  
 22.)GARAGE/RESIDENCE SEPARATION TO COMPLY WITH FBC
 R309.
  
 NEW COMMENT:
  
 23.)SEE ATTACHED FS553.80(2)9B).