2006-11-20 09:09:05DENIED;
 1. PERSON RESPONSIBLE FOR DRAWINGS MUST PRINT AND SIGN
 DRAWINGS.
 2. RISER DIAGRAM DOES NOT MATCH FLOOR PLAN AND CANNOT
 BE INSTALLED AS DRAWN.
 3. AUTOMATIC CLOTHES WASHER NOT SHOWN ON RISER DIAGRAM.
 THE BRANCH DRAIN IS REQUIRED TO BE 3" SECTION 406.3 AND
 A CLEANOUT REQUIRED AT 48"
 ABOVE FINISH FLOOR.
 4. CHANGE NOTE 14 TO WATER HAMMER ARRESTORS.
 5. OUTSIDE SHOWER NOT PERMITED TO TIE INTO DRAINAGE
 SYSTEM. RUN TO DRYWELL OR GRASSY AREA.
 PLUMBING PLAN REVIEW BY;