2006-10-25 16:03:56****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 1.)SHEET S1, ENGINEER SPECIFIES A DESIGN PRESSURE OF
 -80 FOR THE METAL ROOF.THE PRODUCT SUBMITTED HAS A DP
 MAX OF -45PSF.
  
 2.)THE FLAT PORTION OF THE ROOF ON THE PLAN IS
 CONCRETE OVER A STEEL DECK, WITH TAPERED INSULATION
 BOARD.THE PRODUCT APPROVALS SUBMITTED ARE FOR
 MODIFIED OVER STEEL DECK.PLEASE ADDRESS.
  
 3.)FOR THE FLAT ROOF, INDICATE WHICH APPROVED
 ASSEMBLY YOU ARE USING.PRESSURES ARE TO COMPLY WITH
 PRESSURES SPECIFIED BY THE ENGINEER ON THE PLAN, S1.
  
 4.)THE PRODUCT APPROVAL SUBMITTED REQUIRES ENHANCED
 FASTENING TO BE DONE BY AN ARCHITECT, ENGINEER, OR
 REGISTERED ROOF CONSULTANT.PROVIDE CALCULATIONS IN
 ACCORANCE WITH RAS117, SEE ITEM 7 GENERAL LIMITATIONS
 ON THE NOA.
  
 5.)PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER
 OF RECORD, FBC* 106.3.3.