Plan Review Notes For Permit 06100946 |
Permit Number |
06100946 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2006-10-25 16:03:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | 1.)SHEET S1, ENGINEER SPECIFIES A DESIGN PRESSURE OF | | -80 FOR THE METAL ROOF.THE PRODUCT SUBMITTED HAS A DP | | MAX OF -45PSF. | | | | 2.)THE FLAT PORTION OF THE ROOF ON THE PLAN IS | | CONCRETE OVER A STEEL DECK, WITH TAPERED INSULATION | | BOARD.THE PRODUCT APPROVALS SUBMITTED ARE FOR | | MODIFIED OVER STEEL DECK.PLEASE ADDRESS. | | | | 3.)FOR THE FLAT ROOF, INDICATE WHICH APPROVED | | ASSEMBLY YOU ARE USING.PRESSURES ARE TO COMPLY WITH | | PRESSURES SPECIFIED BY THE ENGINEER ON THE PLAN, S1. | | | | 4.)THE PRODUCT APPROVAL SUBMITTED REQUIRES ENHANCED | | FASTENING TO BE DONE BY AN ARCHITECT, ENGINEER, OR | | REGISTERED ROOF CONSULTANT.PROVIDE CALCULATIONS IN | | ACCORANCE WITH RAS117, SEE ITEM 7 GENERAL LIMITATIONS | | ON THE NOA. | | | | 5.)PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER | | OF RECORD, FBC* 106.3.3. |
|