| PROJECT: 2660 TECUMSEH DRIVE: NEW PLANS SUBMITTED |
| DESIGNED BY TARNOWSKI ENGINEERING. |
| |
| |
| 1) AS PER FBC SECTION 2002.2, THE DESIGN, FABRICAITON |
| AND ASSEMBLY OF STRUCTURAL ALUMINUM FOR BUILDINGS OR |
| STRUCTURES SHALL CONFORM TO AA ASM 35 AND |
| SPECIFICATIONS FOR ALUMINUM STRUCTURES, ALUMINUM DESIGN |
| MANUAL, PART 1-A AND 1-B OF THE ALUMINUM ASSOCIATION. |
| |
| 2) FBC SECTION 2002.3.1 ACTUAL WALL THICKNESS OF |
| EXTRUDED ALUMINUM MEMBERS SHALL NOT BE LESS THAN .040 |
| INCH. |
| |
| 3) DISSIMILAR MATERIALS: AS PER FBC SECTION 2003.8.4.2, |
| ALUMINUM CONTACTING METALS NOT CONSIDERED COMPATIBLE |
| SHALL BE PROTECTED AS FOLLOWS: |
| A)PAINTING THE DISSIMILAR METAL WITH A |
| PRIME COAT OF ZINC-CHROMATE PRIMER OR OTHER SUITABLE |
| PRIMER FOLLOWED BY 1 OR 2 COATS OF ALUMINUM MEATAL AND |
| MASONRY PAINT OR OTHER SUITABLE PROTECTIVE COATING, |
| EXCLUDING THOSE CONTAING LEAD PIGMENTATION. |
| |
| B) PAINTING THE DISSIMILAR METAL WITH A |
| COATING OF A HEAVY-BODIED BITUMINOUS PAINT. |
| |
| C)PLACING A GOOD QUALITY CAULKING |
| MATERIAL BETWEEN THE ALUMINUM AND THE DISSIMILAR |
| METAL. |
| |
| D) APPLYING A NONABSORPTIVE TAPE OR |
| GASKET. |
| |
| E) HOT DIPPED GALVANIZING OR ZINC-PLATING |
| STEEL MEMBERS AFTER FABRICATION. |
| |
| 4) AS PER FBC 2003.8.4.3, DISSIMILAR METAKLS SHALL BE |
| PAINTED IF USED IN LOCATIONS WHERE DRAINAGE FROM THEM |
| PASSES OVER ALUMINUM. |
| |
| 5) FBC 2003.8.4.4 ALUMINUM SURAFACES IN CONTACT WITH |
| LIME-MORTAR, CONCRETE OR OTHER MASONRY MATERIALS SHALL |
| BE PROTECTED WITH ALKALI-RESISTANT COATINGS SUCH AS |
| HEAVY BODIED BITUMINOUS PAINT OR WATER WHITE |
| METHACRYLATE LACQUER. |
| |
| 6) FBC 2003.8.405 ALUMINUM IN CONTACT WITH WOOD OR |
| OTHER ABSORBING MATERIALS WHICH MAY BECOME REPEATEDLY |
| WET SHALL BE PAINTED WITH TWO COATS OF ALUMINUM |
| METAL/MASONRY PAINT OR A COAT OF HEAVY BODIED |
| BITUMINOUS PAINT, OR THE WOOD OR OTHER ABSORBING |
| MATERIAL SHALL BE PAINTED WITH TWO CAOTS OF ALUMINUM |
| HOUSE PAINT AND THE JOINTS SEALED WITH A GOOD QUALITY |
| CAULKING COMPOUND. |
| |
| 7) METAL FRAMING WITHIN 5 FT. OF A SWIMMING POOL SHALL |
| BE BONDED AS PER NEC 680-26. |
| |
| 8) FBC 424.2.17.1.11 STANDARD SCREEN ENCLOSURES SHALL |
| MEET THE REQUIREMENTS OF SECTION 424.2.17 RESIDENTIAL |
| SWIMMING BARRIER REQUIREMENT. |