2007-02-20 11:07:00 | |
| *** ISSUED PERMIT*** |
| -PLAN REVIEW HISTORY- |
| |
| PERMIT# 06100574 |
| ADDRESS: 401 CLEMATIS ST |
| CONT: CATALFUMO |
| TELL # (561) 694-3000 |
| |
| THE ATTACHED COMMENTS ARE PART OF THE |
| PERMIT AND PLAN REVIEW PACKAGE AND ARE |
| NOT TO BE REMOVED FROM THE ISSUED SET OF PLANS. 106.1.1 |
| ADMINISTRATIVE CODE/ 06. |
| |
| |
| BUILDING PROVISOS: |
| 1 ) 109.3.10* IMPACT OF CONSTRUCTION. |
| ALL CONSTRUCTION ACTIVITY REGULATED BY |
| THIS CODE SHALL BE PERMORMED IN A MANNER |
| SO AS NOT TO ADVERSELY IMPACT THE |
| CONDITION OF ADJACENT PROPERTY, UNLESS |
| SUCH ACTIVITY IS PERMITTED TO AFFECT |
| SAID PROPERTY PURSUANT TO A CONSENT BY |
| THE APPLICABLE PROPERTY OWNER, UNDER |
| TERMS & CONDITIONS AGREEABLE TO THE |
| APPLICABLE PROPERTY OWNER.THIS INCLUDES |
| BUT IS NOT LIMITED TO THE CONTROL OF |
| DUST, NOISE, WATER OR DRAINAGE RUN-OFF, |
| DEBRIS, AND THE STORAGE OF CONSTRUCTION |
| MATERIALS. NEW CONSTRUCTION ACTIVITY |
| SHALL NOT ADVERSELY IMPACT HISTORIC |
| SURFACE WATER DRAINAGE FLOWS SERVING |
| ADJACENT PROPERTIES, & MAY REQUIRE |
| SPECIAL DRAINAGE DESIGN COMPLYING WITH |
| ENGINEERING STANDARDS TO PRESERVE THE |
| POSITIVE PATTERNS OF THE AFFECTED SITES. |
| ACCORDINGLY, DEVELOPERS, CONTRACTORS, |
| AND OWNERS OF ALL NEW RESIDENTIAL |
| DEVELOPMENT, INCLUDING ADDITIONS, POOLS, |
| PATIOS, DRIVEWAYS, DECKS, OR SIMILAR |
| ITEMS, ON EXISTING PROPERTIES RESULTING |
| IN A DECREASE IN EXCESS OF 800SQ FT OF |
| PERMEABLE LAND AREA ON ANY PARCELL SHALL |
| AS A PERMIT CONDITION, PROVIDE A |
| PROFESSIONALLY PREPARED DRAINAGE PLAN |
| CLEARLY INDICATING COMPLIANCE WITH THIS |
| PARAGRAPH. UPON COMPLETION OF THE |
| IMPROVEMENT, A CERTIFICATE FROM A |
| LICENSED ENGINEER SHALL BE SUBMITTED TO |
| THE INSPECTOR IN ORDER TO RECEIVE |
| APPROVAL OF THE FINAL INSPECTION. |
| |
| 2 ) 109.3.10.1 HURICANE PROTECTION. |
| IT SHALL BE UNLAWFUL FOR ANY PERSON TO |
| ALLOW CONSTRUCTION RELATED MATERIALS |
| EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR |
| OTHERWISE UNSECURED AT A CONSTRUCTION |
| SITE FROM 24 HRS. AFTER A HURRICANE |
| WATCH HAS BEEN ISSUED UNTIL THE |
| HURRICANE WATCH OR WARNING HAS BEEN |
| LIFTED. ALL SUCH CONSTRUCTION MATERIALS, |
| EQUIPMENT AND DEBRIS SHALL BE EITHER |
| REMOVED FROM THE CONSTRUCTION SITE OR |
| SECURED IN SUCH A MANNER AS TO MINIMIZE |
| THE DANGER OF SUCH CONSTRUCTION |
| MATERIALS, EQUIPMENT AND DEBRIS CAUSING |
| DAMAGE TO PERSONS OR PROPERTY FROM HIGH |
| WINDS. |
| ANY PERSONS WHO FAILS TO COMPLY TO |
| REMOVE OR SECURE THE CONSTRUCTION |
| MATERIALS EQUIPMENT AND DEBRIS WITHIN |
| 24 HRS AFTER A HURRICANE WATCH HAS BEEN |
| ISSUED SHALL BE SUBJECT TO A FINE NOT TO |
| EXCEED $500.00. |
| IN ADDITION TO THE ABOVE, A LICENSED |
| CONTRACTOR WHO VIOLATES THIS SECTION |
| SHALL BE SUBJECT TO DISCIPLINE PURSUANT |
| TO SECTION 113 OF THIS CHAPTER. |
| |
| 3) SOUTH SIDE OF LIBRARY ROOF REQUIRES STAIR ACCESS AS |
| PER |
| FBC BUILDING 1009.12 ACCESS TO ROOF. THE PETITIONER |
| SONG& ASSOCIATESHAS MADE APPLICATION FOR A VARIANCE |
| TO |
| THE TECHNICAL CODE, SECTION 1009.12 FBC BUILDING, TO |
| EXCLUDE THE USE |
| OF STAIRS TO GAINACCESS TO THE ROOF AND ALLOW USE OF |
| A SHIPS LADDER |
| TO GAIN ACCESS TO THE ROOF LEVEL. |
| |
| 4) PRE-ENGINEERED ROOF ACCESS HATCHES: RULE 9B-72 / |
| 106.3.3 WEST PALM BEACH |
| ADMINISTRATIVE CODE, BOTH OF THE MENTIONED ABOVE |
| REQUIRE PRODUCT APPROVALS, |
| SINCE THERE ARE NO PRODUCTS AVAILABLE THAT HAVE BEEN |
| TESTED BY THE STATE THEBUILDING CODEADVISORY BOARD |
| OF PALM BEACH COUNTY SENT A LETTER TO DCA ON THIS |
| MATTER AND RECEIVED A DECLATORY STATEMENT FROM THE |
| STATE (DEC04-DCA-161) THAT REQUIRES THE ENFORCEMENT OF |
| THE STATE AND LOCAL PRODUCT APPROVALS. THIS WILL GIVE |
| THE MANUFACTURERS TIME TO GET PRODUCTS TESTED AND ON |
| THE MARKET. NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED |
| UNTIL PRODUCT TESTING FOR WIND LOADS ARE COMPLETED AND |
| PRODUCT APPROVALS FOR PRE-ENGINEERED ROOF HATCHES ARE |
| REVIEWED. |
| |
| 5) TRAINER GLASS COMPANY WILL BE GIVEN 90 DAYS TO |
| COMPLY WITH GLAZING REQUIREMENTS IN THE END ZONES, THEY |
| ARE TO RECEIVE A ONE TIME SITE SPECIFIC NOA FROM |
| MIAMI-DADE FOR CITY HALL FROM THE HURRICANE TEST LAB |
| REPROT # 0062-0310-00. |
| |
| 6) ENGINEERED SHOP DRWINGS FOR THE DOME & BARRELBY |
| TRIODETICSPACE FRAMES INC. SHALL BE REVIEWED BY THE |
| DESIGNER OF RECORD |
| BEFORE SUBMITTED TO THE BUILDING DEPARTMENT. |
| |