Plan Review Notes
Plan Review Notes For Permit 06100524
Permit Number 06100524
Review Stop B
Sequence Number 5
Notes
Date Text
2007-07-10 16:35:25REVISION OF SHEETS S1 - S6 IS DENIED
  
 1) THIS REVISION INCREASES THE VALUE OF THE JOB.
 INDICATE THE AMOUNT OF THE INCREASE ON THE REVISION
 FORM AND HAVE THE INTAKE CLERK ADD THIS TO THE ORIGINAL
 VALUE.
  
 2) ON SHEET S3 ONE OF THE PORCH DIMENSIONS IS MISSING.
 SEE RED MARKS ON THE DRAWING.
  
 3) PROVIDE A SECTION THROUGH THE STAIRS SHOWN AT THE
 MASTER BEDROOM PORCH ON SHEET S3.
  
 4) ON SHEET S4 THERE IS A SECTION TAG FOR 13/S6 AND
 THERE IS NO SUCH SECTION ON SHEET S6. PLEASE CORRECT.
  
 5) ON SHEET S4, (2) 1-3/4"X 11-1/4" 1.95 MICROLAMS
 ARE SPECIFIED AND IN SECTION 9/S6 (2) 1-3/4" X 11-3/4"
 1.9E MICROLAM BEAMS ARE SPECIFIED. PLEASE CORRECT.
  
 6) SPECIFY THE TRUSS CONNECTORS FOR THE MASTER BEDROOM
 PORCH.
  
 7) SECTION 5/S6 ON S4 IS IN THE WRONG LOCATION. IT
 NEEDS TO BE REVISED TO SHOW THE NEW MASTER BEDROOM
 PORCH.
  
 8) IN DETAIL 3 ON S6 SPECIFY WHAT THE 5/8" DIA
 FASTENERS @ 24"OC ARE. ALSO CHECK THE SIMPSON
 CONNECTORS THAT ARE SPECIFIED ( LUZ10 AND HSTC 78).
 THESE COULD NOT BE FOUND IN THE SIMPSON CATALOG. SHOULD
 THESE BE LU210 AND MSTC 78 ?
  
 9) ADDRESS ZONING COMMENTS.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714