Plan Review Notes For Permit 06100093 |
Permit Number |
06100093 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2007-02-12 09:05:49 | DENIED BY BUILDING | | | | 1) THE REVISED SHEETS SUBMITTED ARE FOR THE 2ND FLOOR | | (SUITE 200) OF 307 EVERNIA STREET. THE PERMIT NUMBER ON | | THE REVISION SUBMITTAL FORM (06100093) IS FOR THE THIRD | | FLOOR TENANT BUILD OUT. | | | | 2) SHOW THAT THE DOOR TO THE LOUNGE COMPLIES WITH FBC | | 11-4.13.6 FOR REQUIRED MANEUVERING CLEARANCES AT DOORS. | | A MINIMUM OF 18" IS REQUIRED AT THE LATCH ON THE PULL | | SIDE OF DOORS. | | | | 3) THE LOUNGE CABINET DETAILS ON A6.2.1 DO NOT CLEARLY | | SHOW COMPLIANCE WITH FBC 11-4.24. PROVIDE BETTER | | DETAIL. | | | | 4) ALL PLAN SHEETS THAT ARE AFFECTED THE CHANGES ARE | | REQUIRED TO BE REVISED. SHEET A5.1 IS MISSING. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|