Plan Review Notes
Plan Review Notes For Permit 06100093
Permit Number 06100093
Review Stop P
Sequence Number 1
Notes
Date Text
2006-10-23 13:34:25DENIED;
 1.PLEASE SHOW PLUMBING RISER FOR BREAK SINK, SIZE OF
 SANITARY DRAIN AND VENT. SHOW ON PLANS WERE THE
 BUILDING
 VENT AND SOIL STACKS ARE LOCATED.
 2. SHOW A DETAIL OF THE BREAK SINK. SINK MUST COMPY
 WITH FBC-2004 CHAPTER 11 SECTIONS;
 11-4.24.2 HEIGHT OF SINK.
 11-4.24.3 KNEE CLEARANCE; 27" HIGH, 30" WIDE, AND
 19" DEEP.
 11-4.24.4 DEPTH OF SINK, A MAXIMUM OF 6 1/2" DEEP.
 11-4.24.5 CLEAR FLOOR SPACE 30" X 48" SHOW ON FLOOR
 PLAN.
 11-4.24.6 EXPOSED PIPES TO BE INSULATED.
 11-4.24.7 FAUCET LEVER HANDLES ETC.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695