2006-10-20 08:25:19 | DENIED |
| |
| |
| 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE |
| RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY |
| SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. |
| NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF |
| THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT |
| COMMENCED WITHIN 90 DAYS OF RECORDING. |
| |
| 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 3.BASED ON ICC BUILDING VALUATION DATA THE PERMIT |
| VALUE HAS BEEN REVISED TO $144,527.ADDITIONAL PERMIT |
| FEES ARE DUE. |
| |
| 4.SUBMIT TWO COPIES OF ENERGY CALCS PER 2004 FBC ON |
| FORM 600A-04.COMPLETE TOP SECTION OF FORM.FBC |
| 13-600.3.A |
| |
| 5.PRODUCT APPROVALS REQUIRED FOR IMPACT PROTECTION |
| AND LINTELS.. |
| |
| 6.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY |
| ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL |
| ATTACHED. |
| |
| PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT |
| LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF |
| THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN |
| APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC |
| FORM PER RULE 9B-72. SEE ATTACHMENT. |
| WWW.FLORIDABUILDING.ORG |
| |
| 7.PRODUCT APPROVAL FOR THE OVERHEAD DOOR IS FOR THE |
| WRONG SIZE DOOR. |
| |
| 8.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER |
| 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE |
| APPROVED PRIOR TO INSTALLATION. |
| |
| 9.SAFTEY GLAZING REQUIRED FOR WINDOW AT TUB |
| LOCATIONS.R-308.4 |
| |
| 10.R401.3 DRAINAGE. |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS |
| TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE |
| GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM |
| OF 6 INCHESWITHIN THE FIRST 10 FEET. |
| |
| 11.SUBMIT TWO ORIGINAL SIGNED AND SEALED SURVEYS.FS |
| 472.025 |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE |
| COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A |
| DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET |
| OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| |
| |