Plan Review Notes
Plan Review Notes For Permit 06090459
Permit Number 06090459
Review Stop B
Sequence Number 1
Notes
Date Text
2006-10-12 18:20:20BUILDING PLAN REVIEW
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1) 2004 FL. BLD CODE 1603.1.4 THE
 FOLLOWING INFORMATION RELATED TO WIND
 SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 2)PROVIDE CLEAR AND DETAIL INSTRUCTIONS (PHOTOS)FOR
 THE REMOVAL OF THE AWNINGS DURING PERIODS OF 75MPH
 WINDS VELOCITY, OR THE AWNINGS SHALL BE DESIGN TO
 WITH-STAND WINDS OF 140MPH WITH THEFABRIC IN PLACE
 AND THE FRAME ATTATCHED TO THE BUILDING.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  
  