Date |
Text |
2007-02-12 14:39:15 | DENIED |
| REFERENCE: FBC-2004 PLUMBING |
| FBC-2004 CHAPTER 1 |
| FBC-2004 CHAPTER 11 |
| FBC-2004 BUILDING |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| 1. ALL ARCHITECTURAL SHEETS. THE IMPRESSION SEAL SHALL |
| IMPRESS INFORMATION REQUIRED BY FAC 61G1-16.002(1) & FS |
| 481.2055 ON EACH SHEET. |
| *****RESPONSE NOTED, BUT ALL REQUIRED INFORMATION SHALL |
| BE IMPRESSED ON EACH SHEET, AND THE INFORMATION SHALL |
| BE LEGLBLE. NOT ALL INFORMATION IS LEGIBLE. |
| |
| 2. OK |
| |
| 3. SHT A-104 INDICATE THE SQUARE FOOTAGE AND OCCUPANCY |
| OF THE SERVICE AREA, OIL STORAGE ARE, AND BUSINESS |
| AREAS. SUBMIT CALCULATIONS FOR MINIMUM FACILITIES FOR |
| EACH OCCUPANCY PER TABLES 1004.1.2 & 403.1. SEPARATE |
| FACILITIES ARE REQUIRED FOR EACH SEX PER SECTION 403.2. |
| ONLY MEN'S FACILITIES ARE SHOWN. |
| ****RESPONSE NOTED, BUT THE INFORMATION IS NOT LOCATED |
| ON SHT A-104. ALSO RESPONSE "ALSO PLEASE SEE RESPONSES |
| TO BUILDING PLAN REVIEW" IS NOT TOO CLEAR AS BUILDING |
| HAS 51 COMMENTS. PLEASE INDICATE WHICH COMMENT WILL |
| RESPOND TO MY COMMENT. THIS WILL HELP EXPEDITE THE PLAN |
| REVIEW PROCESS. IT APPEARS THAT THERE ARE SOME AREAS |
| THAT ARE NOT STORAGE. THE PARTS WARRANTY AREA, AND THE |
| LOUNGE/TRAINING AREA.--SECTION 403.3 STATES THAT |
| THE REQUIRED WATER CLOSETS, LAVS, SHALL BE DISTRIBUTED |
| EQUALLY BETWEEN THE SEXES.THE OCCUPANT LOAD SHALL BE |
| COMPOSED OF 50 PERCENT OF EACH SEX, UNLESS STATISTICAL |
| DATA APPROVED BY THE CODE OFFICIAL INDICATE A DIFFERENT |
| DISTRIBUTION OF THE SEXES. |
| |
| 4. SHT A-200 SHOW COMPLIANCE FOR THE FOLLOWING:FOR |
| W/C'S |
| A. OK |
| B. 11-4.16.5 FLUSH CONTROLS |
| ****RESPONSE NOTED, BUT DETAILS 18 & 31 SHOW THE FLUSH |
| CONTROL ON THE WALL SIDE. |
| FOR TOILET STALL |
| A. OK |
| FOR THE URINAL |
| A. OK |
| FOR LAVS |
| A. 11-4.19.2 CLEARANCES |
| ****NOT ADDRESSED |
| B. 11-4.19.5 FAUCETS |
| ****NOT ADDRESSED |
| |
| 5. SHT A-201 SHOW COMPLIANCE FOR THE FOLLOWING:FOR |
| KIT. SINK |
| A. 11-4.24.5 CLEAR FLOOR SINK (FORWARD APPROACH |
| REQUIRED) |
| ****NOT ADDRESSED |
| B. OK |
| |
| 5. OK |
| |
| 6. SHT P-100 BECAUSE OF THE AUTOMOBILE SERVICE WORK AN |
| OIL/GREASE INTERCEPTOR MAY BE REQUIRED. PLEASE CONTACT |
| LYNN MASSON, ENVIRONMENTAL COMPLIANCE MANAGER FOR A |
| DETERMINATION. CONTACT HER AT (561) 822-2271, OR BY FAX |
| (561) 822-2279, OR BY E-MAIL [email protected]. WASTE |
| ORD. 3434. |
| ****WAITING FOR WORD FROM ENVIRONMENTAL COMPLIANCE AS |
| THEY WILL HAVE TO ISSUE THE RESULTS OF THE REQUIREMENT. |
| THERE ARE STILL SERVICE SINKS AND IT WILL BE THEIR |
| DETERMINATION. |
| |
| 7. SHT P-101 SUBMIT MANUF. SPECIFICATION SHEETS FOR THE |
| INSTANT-FLOW WATER HEATER FOR THE KITCHEN SINK. SPECS. |
| SHALL SHOW A LISTING FOR THE W/H. SECTIONS 106.1.2 & |
| 303.4. |
| ****RESPONSE NOTED, BUT MANUF. SPECIFICATION SHEETS |
| WERE NOT LOCATED. |
| |
| 8. SHT P-200 SHOW THE CLEANOUTS AS REQUIRED IN SECTION |
| 1101.8 FOR THE STORM RISERS. |
| ****RESPONSE NOTED, BUT THE CLEANOUTS FOR SECTIONS |
| 708.3.1, 708.3.2, 708.3.3, & 708.3.4 WERE NOT SHOWN ON |
| THE FLOOR PLAN, NOR ON THE RISER DIAGRAMS. |
| |
| 9.OK |
| 10. OK |
| |
| 11. AN RPZV BACKFLOW IS REQUIRED ON THE WATER SUPPLY TO |
| THE BUILDING. SECTION 608.13.2. |
| ****RESPONSE NOTED, BUT AN RPZV BACKFLOW IS REQUIRED ON |
| EACH BUILDING. PLEASE INDICATE A BACKFLOW PRIOR TO THE |
| WATER SERVICE ENTERING THE BUILDING TO SHOW |
| COMPLIANCE. |
| |
| 12. SHT P-200 WATER RISER DIAGRAM. FULL OPEN VALVES |
| REQUIRED ON EACH WATER DOWN-FEED PIPE. SECTION |
| 606.1(4). |
| ****RESPONSE NOTED, BUT THE VALVES ARE NOT SHOWN AT |
| FIXTURES P1, P2, P3, P4, P4, P6 & P9. |
| |
| 13. OK |
| 14. OK |
| 15. OK |
| 16. OK |
| |
| ************NEW COMMENT************* |
| |
| 1B. SHTS A-200 & A-201 ARE OUT OF SEQUENCE IN ONE SET |
| OF PLANS. |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |