Date |
Text |
2008-02-14 13:53:42 | BUILDING PLAN REVIEW |
| PERMIT: 06090243 |
| ADD: 5312 BROADWAY |
| CONT: 3-D HOMES |
| TEL: (561)662-9327 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2005 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW |
| 4TH ACTION: DENIED |
| |
| 1A)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| 1B) INFORMATIONAL ONLY. PLEASE SUBMIT 2 OF ALL SURVEYS, |
| PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR |
| SUBMITTALS FOR REVIEW FOR PERMIT. |
| IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF |
| YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A |
| THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID |
| DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* |
| /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH |
| ADMINISTRATIVE CODE. |
| |
| 1C) INFORMATIONAL ONLY.106.1.1* W.P.B. ADMINISTRATIVE |
| CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN |
| INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO |
| THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO |
| CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION |
| SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE |
| CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR |
| ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. |
| |
| 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| AFTER NOV. 21ST,2005 SHALL BE REVIEWED TO THE 2004 FBC |
| BUILDING WITH THE2005 REVISIONS. |
| |
| 2-4) COMPLIED. |
| |
| 5) COMPLIED. |
| |
| 6-8) COMPLIED. |
| |
| 9) COMPLIED. |
| |
| 9B) SEMI-COMPLIED. THE NEWDOOR SWINGS INTO THE CLEAR |
| FLOOR SPACE REQUIRED BY THE COMMON USE SINKS. |
| |
| 12-16) COMPLIED. |
| |
| 17A) SEMI-COMPLIED. PLANS STILL INDICATE WALLS THAT |
| MAKE UP THE VERTICAL STAIR SHAFT THAT ARE NOT RATED. |
| SEE SHAFTS 707.4. ALSO PROVIDE RATED DOORS FOR THE |
| VERICAL EXIT ENCLOSURE. |
| SEE 715.3. |
| |
| 18-21) COMPLIED. |
| |
| 22)COMPLIED. |
| NEW COMMENTS |
| 23)CORRIDOR WALLS AROUND THE FIRST AND SECOND FLOOR |
| ASSEMBLY OCCUPANCIES THE PLANS DO NOT INDICATE AS RATED |
| WALLS PLEASE SEE TABLE 1016.1. |
| |
| 24)PLANS WILL NEED TO CORRECT THEIR OCCUPANT COUNTS |
| OFFICES ARE 100 SQ FT PER PERSON, AND FIRST FLOOR |
| ASSEMBLY REWRITE 7 SQ FT PER PERSON. |
| |
| 25) THE SECOND FLOOR ONE EXIT IS OUT ONTO THE ROOF, AND |
| DOWN AN EXIT STAIRWAY. THE PLANS SHOW A LINE THAT WOULD |
| INDICATE A CHANGE IN ELEVATION ON THE ROOF. PLEASE |
| PROVIDE |
| WHAT CHANGE IN ELEVATION THIS IS? AND IF STAIRS WOULD |
| BE REQUIRED. |
| |
| |
| |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| E-MAIL: [email protected] |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |