Date |
Text |
2007-03-19 17:42:32 | DENIED |
| REFERENCE: FBC-2004 PLUMBING |
| FBC-2004 BUILDING |
| FBC-2004 CHAPTER 1 |
| FBC-2004 CHAPTER 11 |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| ****FROM PREVIOUS REVIEW: |
| COMMENT NUMBERS TO STAY THE SAME. |
| |
| 1. OK |
| 2. OK |
| 3. OK |
| |
| 4. SUBMIT CALCULATIONS FOR MINIMUM PLUMBING FACILITIES |
| PER TABLES 1004.2 AND 403.1. |
| ****NOT ADDRESSED. IT SEEMS THAT THERE IS MORE THAN A-3 |
| OCCUPANCY. PLEASE SEE SECTION 403.1.1 POTTY PARITY FOR |
| THE A-3 OCCUPANCY. INDICATE ALL OCUPANCIES AND INDICATE |
| THE SQUARE FOOTAGE OF ALL OCCUPANCIES AS WELL AS THE |
| TOTAL OCCUPANCY LOAD OF EACH OCCUPANCY. |
| |
| 5. OK |
| |
| 6. POTTY PARITY IS REQUIRED PER SECTION 403.1.1. THIS |
| IS NOT INDICATED ON PLANS. |
| ****NOT ADDRESSED |
| |
| 7. OK |
| 8. OK |
| |
| 9. SHT 3/5 NEW MEN'S TOILET ROOM STALL DOES NOT COMPLY |
| WITH FIGURE 30E AS REQUIRED IN SECTION 11-4.17.3 |
| EXCEPTION. ALSO A TURNING AREA IS REQUIRED IN THE |
| TOILET ROOMS. PLEASE INDICATE ON PLANS. SECTION |
| 11-4.22.3. |
| ****RESPONSE NOTED, BUT THE TURNING AREA IS NOT SHOWN |
| IN THE TOILET ROOMS AS REQUIRED. (NOT REQUIRED IN THE |
| ACCESSIBLE STALL). |
| |
| 10. SHT 3/5 ELEVATIONS FOR WATER CLOSETS AND LAVS. SHOW |
| THE FOLLOWING INFORMATION: |
| FOR W/C'S |
| A. OK |
| B. 11-4.16.3 HEIGHT (SHOWN AS 20") (NOT ADDRESSED) |
| (17" TO 19") |
| C. OK |
| D. 11-4.16.5 FLUSH CONTROLS (NOT ADDRESSED) |
| FOR LAV'S |
| A. 11-4.19.3 CLEAR FLOOR SPACE (NOT ADDRESSED)B. |
| 11-4.19.5 FAUCETS (NOT ADDRESSED) |
| |
| 11. SUBMIT A DETAIL FOR THE URINAL SHOWING COMPLIANCE |
| WITH 11-4.18 AND ALL SUBSECTIONS. |
| ****RESPONSE NOTED, BUT THE FOLLOWING SECTIONS WERE NOT |
| ADDRESSED: |
| A. 11-4.18.3 CLEAR FLOOR SPACE |
| B. 11-4.18.4 FLUSH CONTROLS |
| |
| 12. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING |
| FOUNTAIN PER 11-4.15 AND ALL SUBSECTIONS, AS WELL AS |
| 11-4.1.3(10)(B) PROVISIONS FOR THOSE WHO HAVE |
| DIFFICULTY BENDING OR STOOPING IF THE DRINKING FOUNTAIN |
| IS NOT A HIGH/LOW UNIT. |
| ****RESPONSE NOTED, BUT A DETAIL FOR THE ACCESSIBLE |
| DRINKING FOUNTAIN HAS NOT BEEN SUBMITTED. |
| |
| 13. SHT 3/5 PLUMBING SANITARY RISER DIAGRAM. URINALS |
| ARE NOT VENTED. SECTION 901.2.1. |
| ****RESPONSE NOTED, BUT THE RISER DIAGRAM DOES NOT |
| REFLECT THE FLOOR PLAN, NOR DOES IT MEET CODE |
| REQUIREMENTS.--THE FLOOR PLAN SHOWS TWO URINALS, |
| BUT THE RISER DIAGRAM SHOW THREE URINALS.--THE |
| DRINKING FOUNTAIN IS NOT SHOWN ON THE RISER DIAGRAM. -- |
| THE LAV IN THEACCESSIBLE STALL IS NOT VENTED.-- THE |
| URINALS STILL ARE NOT VENTED.SECTION 106.1.1. (SEE |
| RED LINE MARKINGS ON THE COPY OF THE RISER DIAGRAM. |
| |
| 14. SUBMIT A WATER RISER DIAGRAM ISOMETRIC. SHOW ALL |
| PIPE SIZES, VALVES, AND WATER HAMMER ARRESTORS AS |
| REQUIRED BY SECTION 604.9. IF WATER HAMMER ARRESTORS |
| ARE INSTALLED, THEY SHALL BE LOCATED NEAR THE FIXTURE |
| IN AN "EFFECTIVE RANGE" NOT IN THE CEILING. PDI-WH 201 |
| AND MANUF. INSTALLATION INSTRUCTIONS. |
| ****NO RESPONSE. NOT ADDRESSED. |
| |
| **********NEW COMMENTS********** |
| |
| 1B. ALL SHEETS. THE ADDRESS FOR THE ENGINEER DOES NOT |
| REFLECT THE ADDRESS ON THE FLORIDA DBPR WEBSITE. PLEASE |
| UPDATE THE WEBSITE OR CHANGE THE TITLE BLOCK. FAC |
| 61G15-23.002(2)&FS 471.025. (SEE ATTACHED DBPR |
| WEBSITE SHEET). |
| |
| 2B. SHT 3/5 MEN'S TOILET ROOM ACCESSIBLE STALL. THE |
| ACCESSIBLE W/C SHALL BE LOCATED IN THE CORNER, DIAGONAL |
| TO THE DOOR. SECTION 11-4.17.3 EXCEPTION (2). |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |