Plan Review Notes For Permit 06090170 |
Permit Number |
06090170 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2006-09-18 00:00:00 | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 1ST | | ACTION: DENIED | | | | 1) 2004 FL. BLD CODE 1603.1.4 THE | | FOLLOWING INFORMATION RELATED TO WIND | | SHALL BE SHOWN ON THE CONSTRUCTION | | DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- INTERNAL PRESSURE COEFFICIENT, | | 5)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | THIS INFORMATION NEEDS TO BE ON THE SHOP | | DRAWINGS DATED 9/5/06. ALSO THE ENGINEER | | THOMAS J. TWOMEY HAS TO SIGN, DATE AND | | SEAL EACH SHEET WHICH HAS HIS NAME AND | | TITLE BLOCK. SEE.F.A.C.61G15-23.002. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL:(561)805-6726 | | | | | | | | |
|