Date |
Text |
2006-09-21 00:00:00 | |
| |
| DENIED |
| |
| 1) THE CLAIMED VALUATION ON THE PERMIT |
| APPLICATION IS LOW. FOR PERMITTING |
| PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT |
| COST EXCLUDING LAND VALUE. OUR VALUATION |
| REFERENCE IS ICC (BVD), MARSHALL-SWIFT |
| AND MEANS COST ANALYSIS SERVICES PER |
| 108.3 FBC* |
| |
| 2) THE DESIGN LOADS AND OTHER |
| INFORMATION PERTINENT TO THE STRUCTURAL |
| DESIGN REQUIRED BY SECTIONS 1603.1.1 |
| THROUGH 1603.1.8 SHALL BE CLEARLY |
| INDICATED ON THE CONSTRUCTION DOCUMENTS |
| FOR PARTS OF THE BUILDING OR STRUCTURE. |
| |
| 3) PROVIDE WIND DESIGN DATA ON DRAWINGS |
| PER 1603.1.4 FBC. THE 2004 FBC NOW |
| REFERENCES ASCE 7-02 |
| |
| 1603.1.4 WIND DESIGN DATA. |
| THE FOLLOWING INFORMATION RELATED TO |
| WIND LOADS SHALL BE SHOWN, REGARDLESS OF |
| WHETHER WIND LOADS GOVERN THE DESIGN OF |
| THE LATERAL-FORCE-RESISTING SYSTEM OF |
| THE BUILDING: |
| 1.BASIC WIND SPEED (3-SECOND GUST), |
| MILES PER HOUR (KM/HR). |
| 2.WIND IMPORTANCE FACTOR, I W , AND |
| BUILDING CLASSIFICATION FROM TABLE |
| 1604.5 OR TABLE 6-1, ASCE 7 AND BUILDING |
| CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| 3.WIND EXPOSURE, IF MORE THAN ONE |
| WIND EXPOSURE IS UTILIZED, THE WIND |
| EXPOSURE AND APPLICABLE WIND DIRECTION |
| SHALL BE INDICATED. |
| 4.THE APPLICABLE ENCLOSURE |
| CLASSIFICATIONS AND, IF DESIGNING WITH |
| ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| 5.COMPONENTS AND CLADDING. THE |
| DESIGN WIND PRESSURES IN TERMS OF PSF |
| (KN/M 2 ) TO BE USED FOR THE DESIGN OF |
| EXTERIOR COMPONENT AND CLADDING |
| MATERIALS NOT SPECIFICALLY DESIGNED BY |
| THE REGISTERED DESIGN PROFESSIONAL. |
| |
| 4) THE PERSONS RESPONSIBLE FOR THE WIND |
| DESIGN SHALL SIGN THE DRAWINGS PER |
| 106.3.4.3 FBC |
| |
| 5) A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT IS REQUIRED PRIOR TO |
| A PERMIT BEING ISSUED |
| |
| BLDG PLAN REVIEW |
| ADRIAN MORSE |
| 561-805-6716 |
| |