Date |
Text |
2007-04-12 15:11:16 | BUILDING PLAN REVIEW |
| PERMIT: 06090011 |
| ADD: 444 W RAILROAD AVE |
| CONT: PBM DEVELOPMENT |
| TEL: (561) 7151800 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 3RD REVIEW |
| ACTION: DENIED |
| |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2) PLEASE PROVIDE A CURRENT NOC. FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| THE COURT. |
| NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3)SHOP DRAWINGS SUBMITTED BY STEADFAST BRIDGES ARE |
| SEALED COPIES OF SIGNATURE NOT ORIGINAL SIGNATURES. |
| PLANS, SPECIFICATIONS, REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE DESIGN |
| PROFESSIONAL AND BEING FILED FOR PUBLIC |
| RECORD SHALL HAVE THE SIGNATURE AND |
| SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| TO THE DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| FL ATATE STAT: 61G16.003 ARCHITECTS |
| |
| 4) PLEASE SEE THE CALCULATIONS SUBMITTED FROM ROBERT G. |
| GRAHAMIII PAGE 39 BASIC LOAD CASES # 8 LL-PEDESTRIAN |
| THE DISTRIBUTED LOAD INDICATES 22. TABLE 1607.1 # 39 |
| WALKWAYS AND ELEVATED PLATFORMS INDICATES A MINIMUM |
| LIVE LOAD OF 60PSF NOT 22. |
| PLEASE CLARIFY. THE OTHER QUESTION ABOUT LIVE LOADS |
| SHEET SHOP DRAWING SHEET# 1 IS THE STATEMENT LIGHT |
| VEHICLE MAXIMUM LOAD 4 TONS IS THIS TO BE CONSIDERED A |
| POINT LOADING? |
| |
| 5) SHOP DRAWINGS (STEADFAST BRIDGES & ROOFING REPORT) |
| SHALL HAVE BEEN REVIEWED BY THE DESIGNER OF RECORD AND |
| THEIR SHOP DRAWING STAMP AFFIXED WITH APPROVAL OR WITH |
| COMMENTS PRIOR TO SUBMITTAL TO THE CITY. |
| WPB ADMIN CODE 106.3* PRODUCT |
| APPROVALS. THOSE PRODUCT WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL.(ROOFING REPORT). |
| |
| 6)SHEET S0.1 PEDESTRIAN BRIDGE HEADING, STILL |
| INDICATES DESIGNED UNDER THE 2001 FBC AND ASCE 7-98, |
| PLEASE CORRECT. |
| |
| 7) CALCULATION BOOKLET COVER SHEET ALSO HAS A RAISED |
| SEALCOPIED SIGNATURE : |
| PLANS, SPECIFICATIONS, REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND |
| BEING FILED FOR PUBLIC |
| RECORD SHALL HAVE THE SIGNATURE AND |
| SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| TO THE DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| FL ATATE STAT: 61G16.003 ARCHITECTS |
| |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER C. B. O. |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| E-MAIL: [email protected] |