Date |
Text |
2006-09-21 00:00:00 | |
| |
| DENIED |
| |
| 1) PROVIDE INFORMATION ON THE "FLEXIBLE |
| COVERING" IF FABRIC IT SHALL BE FLAME |
| RESISTANT PER NFPA 701 AND 3105.1.1.5 |
| FBC (PROVIDE CERTIFICATE) |
| |
| 2) AWNINGS SHALL BE DESIGNED SO THAT |
| FABRIC OR MEMBRANE COVER CAN BE QUICKLY |
| AND EASILY REMOVED PER 3105.4.2.1 |
| TIGHTLY WRAPED OR WOVEN CORDS ARE |
| ACCEPTABLE WHEN 2 COPIES OF A DETAILED |
| INSTRUCTION GUIDE FOR REMOVAL ARE |
| INCLUDED IN THE SUBMITTAL. |
| IN ADDITION 2 COPIES OF A NOTORIZED |
| LETTER OF INTENT TO REMOVE AT 75 MPH ARE |
| REQUIRED.THESE REQUIREMENT ARE NOT |
| NECESSARY IF THE DESIGN IS NON REMOVABLE |
| AND MEETS THE DESIGN WIND LOADS |
| |
| 3) THE CLAIMED VALUATION ON THE PERMIT |
| APPLICATION IS LOW. FOR PERMITTING |
| PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT |
| COST EXCLUDING LAND VALUE. OUR VALUATION |
| REFERENCE IS ICC (BVD), MARSHALL-SWIFT |
| AND MEANS COST ANALYSIS SERVICES PER |
| 108.3 FBC* |
| |
| 4) A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MAY BE REQUIRED PRIOR TO |
| A PERMIT BEING ISSUED IF VALUE IS |
| ADJUSTED |
| |
| BLDG PLAN REVIEW |
| ADRIAN MORSE |
| 561-805-6716 |
| |
| |