2006-11-22 13:51:00PERMIT: 06082221
 ADD: 500 PALM ST SUITE "C"
 CONT: MIKE MOORE CONST
 TEL: (561)748-7000
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3 2ND REQUEST #8 FROM THE PREVIOUS REVIEW,
 FL BLD CODE 1609.1.4 : COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 B) ROOFING ASSEMBLIES
 THE ROOF REPORT SUBMITTED DOESN'T HAVE THE FLORIDA
 COVERSHEET
 NOR ARE THE SUBSYSTEM REPORTSHIGHLIGHTED AS TO WHICH
  
 SUBSYSTEM IS BEING USED. NOTE OVER 1/2 OF THE SUBSYSTEM
 REPORTS ARE FOR
 INSULATED ROOFS. OTHER SUBSYSTEM REPORTS ARE TO BE USED
 ONLY AS AN TILE
 UNDERLAYMENT. PLEASE NOTE MOST OF THE SUBSYSTEM REPORTS
 ONLY HAVE A
 MAXIMUM DESIGN PRESSURE OF -45 TO -60 WITH A LIMITATION
 # 7, NO
 ENHANCED FASTENING!!!!PLEASE HAVE THE DESIGN
 PROFESSIONALS REVIEW
 FOR CODE COMPLIANCE BEFORE SUBMITTAL TO THE CITY
 !!!!!!!!!!!!!!!!!!!!
  
 9) W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  