Plan Review Notes
Plan Review Notes For Permit 06082023
Permit Number 06082023
Review Stop P
Sequence Number 1
Notes
Date Text
2006-09-09 00:00:00DENIED;
 1. ADD NOTE TO PAGE A0.2; ALL PLUMBING
 PIPES NOT BEING RE-USED MUST BE REMOVED,
 AND A DEMO PLUMBING INSPECTION IS
 REQUIRED.SEE FBC-2004 PLUMBING, SECTION
 704.5 NO DEAD ENDS.
 2.NO PLUMBING PAGES FOUND WITH THIS SET
 OF PLANS. PLEASE PROVIDE WATER AND
 SANITARY RISER DIAGRAMS SIZE ALL PIPE
 SHOW LOCATION OF SHUTOFF VALVES AND
 LOCATION OF WATER HAMMER ARRESTORS TO BE
 INSTALLED. ALSO LOCATION OF WATER HEATER
 LISTED ON ELECTRICAL DRAWINGS.
 3.MENS HANDICAP BATHROOM DOOR TO BE
 DIAGONAL OF THE TOILET, SEE FBC-2004
 BUILDING CHAPTER 11 FIG. 30E NOTES.
 4. SHOW A DETAIL OF THE DRINKING
 FOUNTAIN ON PAGE A3.3 WITH HANDICAP
 REQUIREMENTS.