2006-09-20 00:00:00 | |
| |
| BUILDING REVIEW 2ND CHECKLIST |
| (INFORMATION PROVIDED ON FIRST CHECKLIST |
| WAS NOT PROVIDED): |
| |
| ***NOTE: COMMENTS IN CAPITAL LETTERS ARE |
| ORIGINAL COMMENTS. COMMENTS IN LOWER |
| CASE LETTERS ARE THE RESPONSE TO |
| CONTRACTOR'S SUBMITTAL. |
| |
| 1- PROVIDE KEY PLAN AND WINDOWS AND |
| DOORS SIZES. TO VERIFY EGRESS |
| COMPLIANCE. SEC. 106.1.2 CITY AMENDMENTS |
| TO FBC 2004. |
| |
| * NO DONE. |
| |
| 2- PROVIDE OPENING PROTECTION (SHUTTERS |
| OR ANY OTHER MEANS OF GLAZING |
| PROTECTION) AS REQUIRED BY SECTION 507.3 |
| FBC 2004, EXISTING BUILDING. |
| PROVIDE PRODUCT APPROVAL, KEY PLAN AND A |
| COMPLETE INSTALLATION SCHEDULE. SEE |
| ATTACHED SAMPLE OF INSTALLATION SCHEDULE |
| FROM THE CITY IMPLEMENTATION STANDARD |
| FOR WIND-BORNE DEBRIS IMPACT PROTECTION. |
| |
| * NO DONE. |
| |
| 3- ACCORDING TO INSPECTOR'S |
| PRE-INSPECTION AND PICTURES BUILDING HAS |
| ROTTEN AREAS AT OPENINGS FRAMING. NEED |
| TO REPLACE FRAMING AS REQUIRED. PROVIDE |
| COMPLETE STRUCTURAL FRAMING DETAILS FOR |
| DOORS AND WINDOWS INSTALLATION. SEC. |
| 106.1.2 OF CITY AMENDMENTS TO FBC 2004. |
| |
| * NO DONE. |
| |
| 4- THIS PERMIT APPLICATION IS FOR DOORS |
| AND WINDOWS REPLACEMENT ONLY. ACCORDING |
| TO THE INSPECTOR'S PICTURES THERE IS |
| CONSIDERABLE STRUCTURAL DAMAGE TO THE |
| HOUSE. PROVIDE COMPLETE ENGINEERING AND |
| STRUCTURAL PLANS TO PERFORM ALL |
| STRUCTURAL REPAIRS. SEC. 106.1.2 CITY |
| AMENDMENTS TO FBC 2004. |
| |
| * NO DONE. NO INFORMATION SUBMITTED FOR |
| STRUCTURAL REPAIRS EXCEPT FOR RAFTER |
| REPAIRS WHICH WAS DONE UNDER ANOTHER |
| PERMIT. THIS HOUSE NEED COMPLETE |
| ENGINEERING DRAWINGS TO PROVIDE |
| STRUCTURAL STABILITY OF THE BUILDING. |
| SECTION 106.1.2 CITY AMENDMENTS TO FBC |
| 2004. |
| |
| 5- THERE ARE 2 DIFFERENT PRODUCT |
| APPROVALS FOR DOORS SUBMITTED. SUBMIT |
| ONLY THE ONE FOR THE SPECIFIC DOOR TO BE |
| INSTALLED. |
| |
| * ONLY ONE COPY OF DOOR PRODUCT APPROVAL |
| WAS SUBMITTED. NEED 2 COPIES. |
| |
| ** NOW THERE ARE 3 DIFFERENT PRODUCT |
| APPROVALS SUBMITTED FOR SINGLE HUNG |
| WINDOWS. ONE IS NOA 05-0729.03 FL 6585 |
| FOR TRACO WINDOWS. |
| THE OTHER ONE IS FL 6111 FOR H-R |
| WINDOWS, BUT THE DRAWINGS SUBMITTED ARE |
| FOR SIMONTON WINDOWS. FL 6111 IS FOR H-R |
| WINDOWS, NOT FOR SIMONTON WINDOWS. |
| IF USING ALL 3 DIFFERENT WINDOW |
| MANUFACTURERS, THEN PROVIDE COMPLETE |
| PRODUCT APPROVAL PACKAGE FOR EACH ONE. |
| (NOTE: TRACO WINDOWS PRODUCT APPROVAL |
| PACKAGE IS COMPLETE. H-R WINDOWS AND |
| SIMONTON WINDOWS ARE THE ONES WHO NEED |
| COMPLETE PACKAGE). |
| |