Plan Review Notes
Plan Review Notes For Permit 06082016
Permit Number 06082016
Review Stop B
Sequence Number 1
Notes
Date Text
2006-09-09 00:00:00BUILDING REVIEW CHECKLIST:
 1- PROVIDE KEY PLAN AND WINDOWS AND
 DOORS SIZES. TO VERIFY EGRESS
 COMPLIANCE. SEC. 106.1.2 CITY AMENDMENTS
 TO FBC 2004.
  
 2- PROVIDE OPENING PROTECTION (SHUTTERS
 OR ANY OTHER MEANS OF GLAZING
 PROTECTION) AS REQUIRED BY SECTION 507.3
 FBC 2004, EXISTING BUILDING.
 PROVIDE PRODUCT APPROVAL, KEY PLAN AND A
 COMPLETE INSTALLATION SCHEDULE. SEE
 ATTACHED SAMPLE OF INSTALLATION SCHEDULE
 FROM THE CITY IMPLEMENTATION STANDARD
 FOR WIND-BORNE DEBRIS IMPACT PROTECTION.
  
 3- ACCORDING TO INSPECTOR'S
 PRE-INSPECTION AND PICTURES BUILDING HAS
 ROTTEN AREAS AT OPENINGS FRAMING. NEED
 TO REPLACE FRAMING AS REQUIRED. PROVIDE
 COMPLETE STRUCTURAL FRAMING DETAILS FOR
 DOORS AND WINDOWS INSTALLATION. SEC.
 106.1.2 OF CITY AMENDMENTS TO FBC 2004.
  
 4- THIS PERMIT APPLICATION IS FOR DOORS
 AND WINDOWS REPLACEMENT ONLY. ACCORDING
 TO THE INSPECTOR'S PICTURES THERE IS
 CONSIDERABLE STRUCTURAL DAMAGE TO THE
 HOUSE. PROVIDE COMPLETE ENGINEERING AND
 STRUCTURAL PLANS TO PERFORM ALL
 STRUCTURAL REPAIRS. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 5- THERE ARE 2 DIFFERENT PRODUCT
 APPROVALS FOR DOORS SUBMITTED. SUBMIT
 ONLY THE ONE FOR THE SPECIFIC DOOR TO BE
 INSTALLED.
  