2006-10-03 00:00:00 | DENIED |
| |
| |
| 1. 713.13 F.S.A NOTICE OF COMMENCEMENT |
| SHALL BE RECORDED AT PALM BEACH COUNTY |
| COURTHOUSE AND A COPY SUBMITTED TO THIS |
| OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| BLANK FORMS ARE AVAILABLE FROM THIS |
| OFFICE. |
| NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| 90 DAYS OF RECORDING. |
| |
| 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY. THE ACTUAL PERMIT SET OF |
| PLANS MUST BE STAMPED BY THAT OFFICE, |
| AND A COPY OF THE PAID RECEIPT ATTACHED |
| TO THE PERMIT APPLICATION. PLEASE CALL |
| (561)233-5025 FOR MORE INFORMATION. |
| |
| 3.BASED ON ICC BUILDING VALUATION DATA |
| THE PERMIT VALUE HAS BEEN REVISED TO |
| $31,224.ADDITIONAL PERMIT FEES ARE |
| DUE. |
| |
| 4.SUBMIT TWO ORIGINAL SIGNED AND |
| SEALED SURVEYS. FS 472.025 |
| |
| 5.PRODUCT APPROVALS REQUIRED FOR |
| LINTELS. |
| |
| 6.ALL PRODUCT APPROVALS SUBMITTED WITH |
| QUALITY ASSURANCE SHALL HAVE THE |
| FOLLOWING STATE APPROVAL ATTACHED. |
| NOTE:ALL STATE APPROVALS SUBMITTED ARE |
| THE WRONG PAGES EXCEPT THE OVER HEAD |
| DOOR PRODUCT APPROVAL. |
| PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A STATE PRODUCT APPROVAL |
| SHEETS THAT LISTS THE PRODUCT IDENTITY |
| NUMBER FROM THE STATE. IF THE PRODUCT |
| DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT |
| AN APPLICATION FOR LOCAL PRODUCT |
| APPROVAL OR SITE SPECIFIC FORM PER RULE |
| 9B-72. SEE ATTACHMENT. |
| WWW.FLORIDABUILDING.ORG |
| |
| 7.FLAT ROOF PRODUCT APPROVAL.SELECT |
| ASSEMBLY USED AND CHECK GENERAL |
| LIMITATION NUMBER 7.CALCULATIONS MAY |
| BE REQUIRED. |
| |
| 8.SUBMIT TWO SETS OF TRUSS DRAWINGS |
| FOR REVIEW PER 2004 FBC R-802.10.1 |
| TRUSS DRAWING REQUIRED TO BE APPROVED |
| PRIOR TO INSTALLATION. |
| |
| 9.R401.3 DRAINAGE. |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A |
| STORM SEWER CONVEYANCE OR OTHER APPROVED |
| POINT OF COLLECTION SO AS TO NOT CREATE |
| A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| DRAIN SURFACE WATER AWAY FROM FOUNDATION |
| WALLS. THE GRADE AWAY FROM FOUNDATION |
| WALLS SHALL FALL A MINIMUM OF 6 INCHES |
| WITHIN THE FIRST 10 FEET. |
| |
| |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. SUBMIT ONE COPY OF |
| OLD PAGES FOR REFERENCE . A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET |
| OR SPECIFICATION PAGE WHERE THE CHANGES |
| CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |