2007-06-18 10:49:15 | REVISION: WATER HEATER TO BE FUTURE. | | | | ******PROVISO****** | | A) FBC-2004 FUEL GAS SEC. 404.12 OUTLET | | CLOSURES: GAS OUTLETS THAT DO NOT CON- | | NECT TO APPLIANCES SHALL BE CAPPED GAS | | TIGHT. | | B) PER FBC-2004 FUEL GAS, SEC. 623.1, | | AND PER FBC-2004 MECHANICAL, SEC.917.1, | | COOKING APPLIANCES: COOKING APPLIANCES | | THAT ARE DESIGNED FOR PERMANENT | | INSTALLATION, INCLUDING RANGES, OVENS, | | STOVES, BROILERS, GRILLS, FRYERS, | | GRIDDLES AND BARBEQUES, SHALL BE LISTED, | | LABELED AND INSTALLED IN ACCORDANCE WITH | | THE MANUFACTURER'S INSTALLATION INSTRUC- | | TIONS. | | | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | INGS REQUIRED PER SECTION 304.5 OR | | SECTION 304.6 SHALL BE INSTALLED. | | MINIMUM 1,000 CUBIC FEET REQUIRED. | | | | IF WATER HEATER ROOM IS A CONFINED | | SPACE, OPENINGS REQUIRED PER SECTION | | 304.5 OR SECTION 304.6 SHALL BE | | INSTALLED. | | MINIMUM 3,750 CUBIC FEET REQUIRED. |
|