Plan Review Notes
Plan Review Notes For Permit 06080548
Permit Number 06080548
Review Stop B
Sequence Number 2
Notes
Date Text
2007-08-28 15:19:44****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS REVIEW:
  
 1.)IMPACT PROTECTION REQUIRED, FBC R 301.SHUTTERS
 ARE TO BE IN COMPLIANCE WITH FLORIDA BUILDING CODE.
 PROVIDE A PERMIT NUMBER FOR THE EXISTING SHUTTERS.
  
 NEW COMMENT:
  
 2.)SEE FBC*105.4.1, CONDITIONS OF THE PERMIT."A
 PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO
 PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE,
 CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE
 TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
 THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A
 CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR
 VIOLATIONS OF THIS CODE."BUILDING OFFICIAL HAS
 REVIEWED YOUR REQUEST TO ISSUE THE REVISION AND HAS
 REFERRED ME TO THIS CODE SECTION.
  
 THE INITIAL PERMIT WAS ISSUED IN ERROR BASED ON THE
 STATEMENT BY CONTRACTOR THAT SHUTTERS WERE EXISTING.
 SEE FBC EXISTING BUILDING CODE 507.3, REPLACEMENT OF
 WINDOWS AND DOORS, REQUIRE WINDOWS TO COMPLY WITH FBC
 CHAPTER 16.FBC1609.1.4 REQUIRES IMPACT PROTECTION
 WHICH COMPLIES WITH SSTD12, ASTM E1886 & ASTM E1996,
 OR MIAMI-DADE TAS201, 202 & 203 OR AAMA 506.AS IT
 APPEARS THAT THE EXISTING SHUTTERS WERE NOT PERMITTED,
 THEY CANNOT BE USED TO COMPLY WITH THIS CODE
 REQUIREMENT.
  