Plan Review Notes
Plan Review Notes For Permit 06080338
Permit Number 06080338
Review Stop B
Sequence Number 2
Notes
Date Text
2007-01-13 11:22:20BUILDING PLAN REVIEW
 PERMIT:06080338
 ADD:?
 CONT: ECD
 TEL: (561)822-1252
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1)THE ADDRESS ON THE APPLICATION AND DRAWINGS DOES
 NOT MATCH THE ONE IN OUR SYSTEM. CLARIFY.
  
 2)106.1 IF THE DESIGN PPOFISSIONAL IS AN ARCHITECT OR
 ENGINEER LEGALLY REGISTERED UNDER THE LAWS OF THIS
 STATE TEGULATING THE PRACTICE OF ARCHITECTURE AS
 PROVIDED FOR IN CHAPTER 481 OR 471 OF THE FLORIDA
 STATUTES,THEN HE ODR SHE SHALL AFFIX HIS OR HER
 OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA AS REQUIRED BY
 FLORIDA STATUTE.
  
 3)ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13.
  
 _XX___2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED
 POLICY:MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE /
 AREA OF EACH ROOF TYPE
  
 ____3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX___4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS.
  
 _XX___5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
  
 _XX__ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING.
  
 _XX___ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
  
 NOTE: FBC 1609.6.6.2THE SYSTEM SELECTED
 FROM THE SUBMITTED FLAT ROOF PRODUCT
 APPROVAL NOA HAS A MAXIMUM DESIGN
 PRESSURE OF LESS THAN -89 PSF AND CITES
 GENERAL LIMITATION #9.GENERAL LIMITATION #9
 PROHIBITS
 RATIONAL ANALYSIS OR EXTRAPOLATION TO
 ENHANCE THE UPLIFT PRESSURE AT PERIMETER
 AND CORNER AREAS BY REDUCING THE
 FASTENER SPACING IN THESE AREAS.EITHER
 SELECT AN ALTERNATIVE SYSTEM (OR PRODUCT
 APPROVAL) THAT DOES NOT CITE GENERAL
 LIMITATION #9.ALTERNATIVELY IF THE
 SELECTED SYSTEM DOES CITE GENERAL
 LIMITATION #9, IT MUST HAVE A MAXIMUM
 DESIGN PRESSURE THAT EXCEEDS THE
 PRESSURE IN ROOF ZONE 3 (TYPICALLY -89
 PSF FOR MEAN ROOF HEIGHT OF 30 FEET OR
 LESS).
  
 4)THE PRODUCT APPROVALS ARE MISSING THE FLORIDA STATE
 APPROVAL COVER SHEETS.
  
 5)SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS
 APPLY
  
 _XX___1.PROVIDE BUILDING HEIGHT ON THE PLAN.
 DESIGN PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED
 TO BE DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE
 DONE BY AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 _XX___2.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 _XX___3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 _XX___4.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 _XX___5.SHOW THE EMERGENCY MEANS OF ESCAPE,
  
 _XX___ 6.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 6)INDICATE THE OCCUPANT LOAD OFF THE BUILDING ON THE
 DRAWINGS. SEE FBC 1004.
  
 7)FBC 302.3WHERE A BUILDING IS OCCUPIED BY TWO OR
 MORE USES NOT INCLUCED IN THE SAME OCCUPANCY
 CLASSIFICATION, THE BUILDING OR PORTION THEREOF SHALL
 COMPLY WITH SECTION 302.1 OR 302.3.2 OR A COMBINATION
 OF THESE SECTIONS. THEREFORE IF THERE IS MORE THAN ONE
 TYPE OF OCCUPANCY, THE OCCUPANCY HAS TO REFLECT THE
 CORRECT USE ACCORDING FBC SEC.302.
  
 8)THE DESCRIPTION ON THE APPLICATION HAS TO BE MORE
 SPECIFIC TO SHOW THE WORK THAT WILL BE DONE ON THE
 PROJECT.
  
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  
  
  