Plan Review Notes
Plan Review Notes For Permit 06080304
Permit Number 06080304
Review Stop B
Sequence Number 2
Notes
Date Text
2007-01-08 19:00:11BUILDING REVIEW SECOND CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTES.
  
 2- A) REVISE SURVEY. FLOOD ZONE IS "C" PER COMMUNITY
 PANEL 120229 0015 B OF MARCH 1ST, 1979. NOTX N/A. B)
 BOTH COPIES TO HAVE ORIGINAL SEAL AND SIGNATURE AS
 REQUIRED BY CHAPTER 472 FLORIDA STATUTES.
  
 3- NEED ENERGY CALCULATIONS AS REQUIRED BY CHAPTER 13
 FBC 2004.
  
 4- 24 SH WINDOW DOESN'T COMPLY WITH BEDROOM EGRESS
 REQUIREMENTS OF SEC. R310.1.2 2004 FLORIDA RESIDENTIAL
 CODE.
  
 5- A) PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS.
 NEED A KEY PLAN AND COMPLETE INSTALLATION SCHEDULE. SEE
 ATTACHED SAMPLE OF INSTALLATION SCHEDULE THAT CONTAINS
 ALL NECESSARY INFORMATION TO PERFORM PLAN REVIEW.OR
 PROVIDE ANY OTHER MEANS WHICH WILL SHOW ALL THE
 REQUIRED INFORMATION FOR PLAN REVIEW. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 B) PROVIDE PRODUCT APPROVAL FOR STORM SHUTTERS.
 ENGINEER TO REVIEW AND APPROVE IT IN WRITING (NOT
 SIGNING AND SEALING) AS REQUIRED BY SEC. 108.3 CITY
 AMENDMENTS TO FBC 2004.
  
 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR :
 FLAT ROOF SYSTEM:
 A)IDENTIFY SPECIFIC APPROVED ASSEMBLY TO BE
 INSTALLED, SPECIFIC FASTENING OPTION. IF SELECTED
 SYSTEM IS LIMITED BY GENERAL LIMITATION #7, THEN
 PROVIDE INFORMATION AS REQUESTEDON GENERAL LIMITATION
 #7.IF SELECTED APPROVED ASSEMBLY IS LIMITED BY
 GENERAL LIMITATION #9, THEN SYSTEM MAY NOT BE USED
 BECAUSE LIMITATION #9 DOESN'T ALLOW NAIL ENHANCINGAS
 REQUIRED AT PERIMETER AND CORNER AREAS. SEE GENERAL
 LIMITATIONS ON PRODUCT APPROVAL. SEE ATTACHED COPY OF
 CITY POLICY FOR ROOFING PERMITS AND PROVIDE ALL
 REQUIRED INFORMATION.
  
 B) SPECIFY BASE SHEET FASTENING OPTION ON SELECTED
 APPROVED ASSEMBLY. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 C) ENGINEER TO REVIEW AND APPROVE IN WRITING PRODUCT
 APPROVAL AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO
 FBC 2004.
  
 7- BUILDING PERMIT VALUATION WAS TOO LOW. IT WAS
 UPDATED TO $30,788. OWES $1670.98 FOR PERMIT VALUATION
 AND RADON FEES.
  
 8- SHEET 4:
 A) SPECIFY SIZE (HOW LONG, HOW MUCH EMBEDMENT) FOR
 ANCHOR BOLT AT EXISTING WALL LEDGER. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 B) GIVEN THE TYPE OF ROOF NEED TO PROVIDE CONTINUOUS
 RIDGE VENT IN ORDER TO PROVIDEVENTILATION. (3) 8"X16"
 SPREADED VENTS DON'T PROVIDE CROSS VENTILATION BETWEEN
 THE SOLID JOIST.SEC. R806 2004 FLORIDA RESIDENTIAL
 CODE. REVISE AS REQUIRED.
  
 C) SPECIFY SIZE (HOW LONG, HOW MUCH EMBEDMENT) FOR
 HTT22 CONNECTOR. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 D) SPECIFY CALCULATED DESIGN PRESSURES FOR EXTERIOR
 DOOR BY UTILITY AREA. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004 AND SEC. R301 2004 FLORIDA RESIDENTIAL CODE.
  
 E) DESIGN PRESSURES CALCULATIONS FOR WINDOWS ARE TOO
 LOW ACCORDING TO WINDOW SIZE AND LOCATION. PROVIDE
 ACTUAL CALCULATIONS SHOWING HOW DESIGN PRESSURES WERE
 CALCULATED. SEC. 106.1.2 CITY AMENDMENTS TOFBC
 2004.
  
 9- CONTRACTOR TO UPDATE THE LICENSE RECORDS WITH THE
 PERMIT CLERK.
  
 10- SPECIFY LEVEL OF ALTERATION AS REQUIRED BY SECTION
 301.5 OF 2004 FLORIDA EXISTING BUILDING CODE.
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712