Date |
Text |
2006-10-05 00:00:00 | DENIED |
| |
| |
| 4.R401.3 DRAINAGE. |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A |
| STORM SEWER CONVEYANCE OR OTHER APPROVED |
| POINT OF COLLECTION SO AS TO NOT CREATE |
| A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| DRAIN SURFACE WATER AWAY FROM FOUNDATION |
| WALLS. THE GRADE AWAY FROM FOUNDATION |
| WALLS SHALL FALL A MINIMUM OF 6 INCHES |
| WITHIN THE FIRST 10 FEET. |
| ( SHOW HOW COMPLIANCE WITH THE ABOVE |
| WILL BE COMPLETED.COPY OF THE CODE |
| SECTION ON PLAN IS NOT SUFFICIENT.) |
| |
| 5.LOCATION ON LOT,PROJECTIONS |
| EXTENDING INTO THE 6-FOOT SEPARATION |
| DISTANCE SHALL HAVE NOT LESS THAN 1-HOUR FIRE-RESISTIVE |
| CONSTRUCTION ON THE |
| UNDERSIDE. THE ABOVE PROVISIONS SHALL |
| NOT APPLY TO WALLS WHICH ARE |
| PERPENDICULAR TO A LINE EXTENDING FROM |
| THE POINT FROM WHICH THE SEPARATION |
| DISTANCE HAS BEEN MEASURED RUNNING AND |
| PARALLEL TO THE PROPERTY LINE. |
| SHOW MORE THAN SIX FOOT SEPERATION OR |
| SHOW COMPLIANC WITH THIS SECTION R302.1 |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. SUBMIT ONE COPY OF |
| OLD PAGES FOR REFERENCE . A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET |
| OR SPECIFICATION PAGE WHERE THE CHANGES |
| CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| ART LANGE |
| CONSTRUCTION SERVICES DEPARTMENT |
| BUILDING PLANS EXAMINER |
| 561-805-6672 |
| |