Date |
Text |
2006-08-22 00:00:00 | DENIED |
| REFERENCE: FBC-2004 PLUMBING |
| FBC-2004 BUILDING |
| FBC-2004 CHAPTER 1 |
| FBC-2004 CHAPTER 11 |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| NFPA 99C |
| |
| 1. ALL ARCHITECTURAL SHEETS. THE ADDRESS |
| OF THE ARCHITECTURAL BUSINESS ON THE |
| TITLE BLOCK DOES NOT REFLECT THE ADDRESS |
| SHOWN ON THE RECORDS AT DBPR. (SEE |
| ATTACHED SHEET). PER FAC 61G1-16.004(1) |
| THE ADDRESS MUST BE SHOWN IN THE TITLE |
| BLOCK. FS 481-2055. |
| |
| 2. ALL ARCHITECTURAL SHEETS. THE SEAL |
| SHALL CONTAIN THE REGISTRATION NUMBER OF |
| THE ARCHITECT. NO NUMBER HAS BEEN |
| IMPRESSED ON THE SHEETS IN THE SEAL. FAC 61G1-16.002(1) |
| & FS 481.2055. |
| |
| 3. SHTS A2.01 & A2.02 THE FIRST FLOOR |
| FINISH SCHEDULE FOR ROOMS 103, 104, 118, |
| (WOMEN, UNISEX HDCP, & MEN TOILET ROOMS) |
| AS WELL AS ROOMS 202, 205, 208, & 210 |
| TOILET ROOMS INDICATE PAINTED MR GWB FOR |
| THE WALLS. PLEASE SHOW HOW THIS COMPLIES |
| WITH SECTION 1210.2 REQUIREMENTS FOR |
| WALLS TO BE HARD & NON-ABSORBENT. |
| |
| 4. SHT A2.01 THE BREAK ROOM SINK AND SHT |
| A2.02 THE STAFF LOUNGE SINK SHALL BE |
| ACCESSIBLE. SUBMIT DETAILS SHOWING |
| COMPLIANCE WITH SECTION 11-4.24 AND ALL SUBSECTIONS. |
| (FORWARD APPROACH REQUIRED, |
| AND NO CABINET DOORS ALLOWED IN CLEAR |
| FLOOR SPACE). |
| |
| 5. SHT A6.01 UNISEX TOILET ROOM - 104 |
| SHOW THE CLEAR FLOOR SPACE FOR THE W/C |
| AND LAV, AND SHOW THE TURNING AREA. |
| SECTIONS 11-4.16.2, 11-4.16.3, AND |
| 11-4.22.3. |
| |
| 6. SHT A6.01 DETAILS 1, 2, 3, & TOILET |
| ACCESSORY LEGEND REFERENCE COMPLIANCE |
| WITH 1997 EDITION ACCESSIBILITY. DESIGN |
| REQUIRED TO BE COMPLIANT WITH FBC-2004 |
| CHAPTER 11. PLEASE CHANGE REFERENCE. |
| |
| 7. SUBMIT A DETAIL SHOWING COMPLIANCE |
| WITH SECTION 11-4.15 AND ALL SUBSECTIONS |
| FOR THE DRINKING FOUNTAINS. |
| |
| 8. SHTS P3.1 & P3.2 AND RPZV BACKFLOW IS |
| REQUIRED ON THE WATER SERVICE AS CLOSE |
| TO THE METER AS POSSIBLE, ON PRIVATE |
| PROPERTY. SECTION 608.13.2 AND MUNICIPAL |
| ORDINANCE 2853-95. |
| |
| 9. SHT P3.2 FULL OPEN VALVES SHALL BE |
| INSTALLED ON THE BASE OF EVERY WATER |
| RISER PIPE, AND ON THE TOP OF EVERY |
| WATER DOWN-FEED PIPE. SECTION 606.1(3) & 606.1(4). |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |