Plan Review Notes For Permit 06071589 |
Permit Number |
06071589 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2006-08-05 00:00:00 | | | | | DENIED | | | | 1) ACCORDIAN SHUTTERS ARE INSTALLED WITH | | SPANS VERTICAL PLEASE CHANGE ORIENTATION | | AND SHUTTER SPANS SEE PAGE 4 OF SHUTTER | | DRAWINGS. NOTE THAT THE SHTTER SPAN | | (WITH 3" E.D.) IS GENERALLY 2" BIGGER | | THAN THE OPENING ON WINDOWS AND APPROX | | THE SAME AS THE OPENING FOR DOORS | | | | 2) BECAUSE ALL ATTACHMENT TYPES ARE | | CHOSEN ASSUMPTIONS ARE MADE THAT SHUTTER | | #2 IS A DOOR AND THAT A FLOOR MOUNTED | | SILL WILL BE USED. PLEASE SEE THAT AT AN | | 11 FT SPAN THE ANCHOR SPACING IS LESS | | THAN THE STATED SPACING ON THE | | INSTALLATION SCEDULE | | | | 3) ALSO SEE THAT PANEL SPANS CAN BE | | MOUNTED IN EITHER DIRECTION HOR. OR VERT | | BUT THE SPANS CHOSEN DO NOT MATCH EITHER | | EG. #3 SEE PAGE 2 OF DRAWING PANEL | | LENGTH = PANEL SPAN, SPAN = OPENING + | | EDGE DISTANCE + 2" (FOR DISTANCE FROM | | ANCHOR TO END OF PANEL X 2) | | | | 4) PROVIDE 2 COPIES OF ALL SUBMITTALS | | (INCLUDING INSTALLATION SCHEDULE) | | | | ADRIAN MORSE | | BLDG PLAN REVIEW | | 561-805-6716 | | | | |
|