2006-07-25 00:00:00 | ******DENIED****** |
| REFERENCE: FBC-2004 FUEL GAS |
| FBC-2004 CHAPTER 1 |
| |
| THE FOLLOWING IS REQUIRED FOR GAS PLAN |
| REVIEW: |
| |
| 1. PER FBC-2004 CHAPTER 1, SECTIONS |
| 109.3 REQUIRED PERMITS AND SECTION 109.6 |
| APPROVAL REQUIRED: THIS PERMIT CANNOT BE |
| ISSUED UNTIL THE EXPIRED GAS PERMIT |
| #03110020 HAS BEEN TAKEN CARE OF. PLEASE |
| SEE ATTACHED PERMIT INFORMATION FOR |
| REFERENCE. |
| 2. SUBMIT AN ISOMETRIC DRAWING THAT |
| CLEARLY SHOWS ALL CUT SECTIONS OF PIPE |
| AND CORRESPONDING LENGTHS PER FBC-2004 |
| FUEL GAS CODE. |
| 3. TYPE OF GAS, (LP OR NATURAL) |
| 4. BTU LOAD OF EACH APPLIANCE AND THE |
| TOTAL BTU LOAD ON THE SYSTEM. REFER TO |
| THE FBC-2004 FUEL GAS CODE SECS. 401.8 |
| THRU 402.6.1 AND TABLES 402.4(1) THRU |
| 402.4(33). (NOTE: PERMIT INFORMATION |
| INDICATES EXISTING GAS TO A GRILL ON |
| EXPIRED PERMIT #03110020, TOTAL BTU LOAD |
| NEEDS TO BE INDICATED ON ISOMETRIC.) |
| 5. SHOW THE DISTANCE FROM THE POINT OF |
| DELIVERY, (METER), TO THE MOST REMOTE |
| OUTLET IN THE BUILDING AND/OR SYSTEM PER |
| FBC-2004 FUEL GAS CODE APPENDIX A - USE |
| OF CAPACITY TABLES A.3.1(4). ( NOTE: |
| THIS INCLUDES EXISTING GAS TO GRILL) |
| 6. SUBMIT MANUFACTURE SHEETS FOR ALL GAS |
| EQUIPMENT TO VERIFY COMPLIANCE WITH |
| STANDARDS NFPA 54, NFPA 58, AND THE |
| FBC-2004 FUEL GAS CODE SEC 402.2 |
| (NOTE: NEED MANUFACTURE CUT SHEETS ON |
| 2LB REGULATORS) |
| 7. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: |
| THE PERSON RESPONSIBLE FOR THE DESIGN OF |
| THE DRAWING SHALL CLEARLY PRINT AND SIGN |
| NAME, AND ALSO DATE DRAWING. PLEASE DO |
| THIS PRIOR TO RESUBMITTING. |
| |
| **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN |
| RESUBMITTING, PLEASE REPLACE ONLY SHEETS |
| WHICH HAVE CHANGED AND PROVIDE ONE COPY |
| OF ALL OLD/VOIDED SHEETS FOR REFERENCE |
| ONLY. PLEASE SEE CORRECTED ISOMETRIC GAS |
| RISER DIAGRAM IN RED INK FOR REFERENCE |
| FOR RESUBMITTAL. |
| |
| END OF COMMENTS: |
| |
| REVIEW BY MIKE PERSON |
| (561) 805-6730 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |
| UNDER SUPERVISION OF K.STEVENS |
| (561) 805-6721 |
| |
| |
| |
| |
| |
| |
| |
| |