2006-08-19 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ALL SHEETS DESIGNED BY THE REGISTERED ARCHITECT. THE
 ORIGINAL SIGNATURE IS
 REQUIRED ON THE SEAL, AND THE BUSINESS
 LICENSE NUMBER, (CERTIFICATE OF
 AUTHORIZATION), IS REQUIRED IN THE TITLE
 BLOCK OF EACH SHEET. 61G1-16.004(1)(5)
 AND FS 481.219 481.2055.
  
 2. SHT D1 DEMO REQUIREMENTS #'S 2 & 3
 DEAD ENDS ARE NOT ALLOWED. SECTION
 704.5.
  
 3. SHT D1 GREASE INTERCEPTORS SHALL BE
 PUMPED OUT AND WASHED DOWN PRIOR TO
 REMOVING.
  
 4. SHTS A1, A5.2 & A9 BREAK ROOM SINK
 SHALL BE ACCESSIBLE. PLEASE SUBMIT A
 DETAIL SHOWING THE FOLLOWING:
 A. 11-4.24.3 KNEE CLEARANCE
 B. 11-4.24.4 SINK DEPTH
 C. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD
 APPROACH REQUIRED. NO CABINET DOORS
 ALLOWED IN CLEAR FLOOR SPACE).
 D. 11-4.24.7 FAUCETS
  
 5. SHT A5.3 DRINKING FOUNTAIN TO BE
 ACCESSIBLE. SUBMIT A DETAIL SHOWING THE FOLLOWING:
 A. 11-4.15.2 SPOUT HEIGHT
 B. 11-4.15.5 CLEARANCES AND CLEAR FLOOR
 SPACE. (FORWARD APPROACH REQUIRED).
  
 6. SHT A5.2 DETAIL 1 INDICATES A SINK
 WITH AN EYEWASH STATION. MORE
 INFORMATION REQUIRED. PLEASE SUBMIT A
 DETAIL AND MANUFACTURE SPECIFICATION & INSTALLATION
 SHEETS.
  
 7. A5.3 FAMILY TOILET ROOM, (129),
 WOMENS TOILET ROOM, (130), MEN'S TOILET
 FOOM, (127). SHALL BE ACCESSIBLE. SUBMIT
 THE FOLLOWING:
 FOR W/C'S...
 A. 11-4.16.3 HEIGHT
 B. 11-4.16.4 GRAB BARS
 C. 11-4.16.5 FLUSH CONTROLS
 D. 11-4.16.6 DISPENSERS
 FOR STALLS....
 A. 11-4.17.3 EXCEPTION 2 THE ACCESSIBLE
 W/C SHALL BE LOCATED IN THE CORNER,
 DIAGONAL TO THE DOOR. (SEE MENS TOILET
 ROOM).
 FOR URINALS...
 A. 11-4.18.2 HEIGHT
 B. 11-4.18.4 FLUSH CONTROLS
 FOR LAVS....
 A. 11-4.19.2 HEIGHT & CLEARANCES
 B. 11-4.19.4 EXPOSED PIPES & SURFACES
 C. 11-4.19.5 FAUCETS
 D. 11-4.19.6 MIRRORS
  
 8. SHT A5.3 DETAIL 6 TOILET ELEVATION
 FOR THE ACCESSIBLE STALL DOES NOT SHOW
 THE LAV. SECTION 106.1.1.
  
 9. SHT A5.3 FAMILY TOILET, W/C TO BE 18"
 OFF THE WALL TO CENTERLINE OF THE
 FIXTURE. SEE FIG. 28.
  
 10. ALL PME & REFRIG. SHEETS. ENGINEERS
 SHALL LEGIBLY INDICATE THEIR NAME, AND
 LICENSE NUMBER, AS WELL AS, THE NAME,
 ADDRESS AND CERTIFICATE OF AUTHORIZATION
 NUMBER OF THE ENGINEERING BUSINESS ON
 EACH SHEET. 61G15-23.002(2) & FS 471.025
  
 11. SHT P1 GREASE INTERCEPTORS SHALL BE
 SIZED BY THE UTILITY DEPT. ENVIRONMENTAL COMPLIANCE
 MGR. PLEASE CONTACT LYNN
 MASSON, (561) 822-2271, FAX (561)
 822-2279, OR E-MAIL [email protected] FOR
 A DETERMINATION ON INTERCEPTOR SIZE.
 WASTE ORDINANCE #3434.
  
 12. SHT P1 CLEANOUTS REQUIRED PER
 SECTIONS 708.3.1, 708.3.3, & 708.3.5
 REQUIRED ON THE SANT., GREASE, AND
 CONDENSATE SYSTEMS.
  
 13. SHT P1 INDICATES REMOVAL OF ALL
 FLOOR DRAINS. IN THE INSTALLATION OR
 REMOVAL OF ANY PART OF A DRAINAGE SYSTEM
 DEAD ENDS SHALL BE PROHIBITED. SECTION
 704.5.
  
 14. SHT P1 MINIMUM FACILITIES REQUIRES
 TWO DRINKING FOUNTAINS. ONLY A HI/LOW
 DRINKING FOUNTAIN IS SHOWN. IF A FIXTURE
 HAS ONLY ONE DRAIN LINE AND ONE SUPPLY
 LINE IT IS CONSIDERED ONE FIXTURE.
 PLEASE INDICATE THE LOCATION OF EWC-1 AS
 SHOWN ON SHT P4 PLUMBING FIXTURE
 SCHEDULE. TABLE 403.1.
  
 15. SHT P-3 WATER HAMMER ARRESTORS ARE
 REQUIRED AT ALL QUICK CLOSING VALVES,
 SUCH AS DISH WASHERS, ICE MAKERS, ETC.
 PLEASE SHOW ONE AT THE ICE MAKER. ALL
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 NEAR THE FIXTURES, IN AN "EFFECTIVE
 RANGE" NOT IN THE CEILING AS SHOWN AT
 THE LAVS IN MENS AND WOMENS TOILET ROOM.
 SECTION 604.9 AND PDI-WH 201.
  
 16. SHT P3 2 WAY CLEANOUTS ARE REQUIRED
 AT THE INLET AND EXIT OF EACH GREASE
 INTERCEPTOR.
  
 17. SHT P3 THE SANT. RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN BETWEEN
 FIXTURE AND 1ST FIXTURE.
 SHOW ALL PIPE SIZES ON THE RISER
 DIAGRAM. SECTION 106.1.1 AND TABLES
 710.1(1) & 710.1(2).
  
 18. SHT P4 COFFEE BAR PLUMBING EQUIPMENT CONNECTION
 SCHEDULE CO8. SUBMIT MANUF SPECIFICATION SHEETS FOR THE
 WATER
 FILTER. FILTER SHALL COMPLY WITH NSF 42.
  
 19. SUBMIT A CONDENSATE RISER DIAGRAM
 ISOMETRIC SHOWING ALL PIPE SIZES.
 SECTION 106.3.5.1.3.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]