2006-07-17 00:00:00BUILDING REVIEW CHECKLIST:
 1- TRUSS PACKAGE IS INCOMPLETE. ONLY
 TRUSS LAYOUT WAS SUBMITTED. NEED TO
 SUBMIT COMPLETE TRUSS PACKAGE INCLUDING
 THE INDIVIDUAL TRUSSES.
 ***NOTE; MAKE SURE ALL TRUSS DRAWINGS
 ARE SIGNED, SEALED AND WITH ENGINEER'S
 INFORMATION AS REQUIRED BY CHAPTER 471
 FL. ST.AND SEC. 61G15-23.002 FAC.
  
 2- TRUSS DRAWINGS TO SPECIFY BUILDING
 CODE FOR WHICH THEY WERE DESIGNED.
  
 3- ENGINEER TO SPECIFY ROOF SHEATHING
 NAILING. SEE TABLE 2304.9.1 FBC 2004.
  
 4- SPECIFY UPLIFT LOADS AND TRUSS ANCHOR
 SCHEDULE. SEC. 1609FBC 2004 AND SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 5- A) PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL AS REQUIRED BY RULE 9B-72 FOR
 ALL TRUSS CONNECTORS SPECIFIED.
 B) DESIGNER OF RECORD TO REVIEW AND
 APPROVE IN WRITTING ALL PRODUCT
 APPROVALS AS REQUIRED BY SEC. 106.3.3 OF
 CITY AMENDMENTS TO FBC 2004
  
  
 6- ROOF PITCH OF 2.5:12 REQUIRES 2
 LAYERS OF UNDERLAYMENT. SEC. 1507.2.2
 FBC 2004.
  