2006-08-08 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 06070002 |
| ADD: 1601 FORUM PLACE |
| CONT: PASS INTERNATIONAL |
| TEL: (954)496-3133 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| THAT IS REQUIRED FOR RECORD |
| KEEPING & FOR CERTIFICATE OF OCCUPANCY: |
| A) THE EDITION OFTHE CODE UNDER WHICH |
| THE PERMIT WAS ISSUED. |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| WITH THE PROVISIONS OF CHAPTER 3. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED |
| IN CHAPTER 6, TABLE 601. |
| D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| IS REQUIRED. |
| F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| OF THE BUILDING PERMIT. |
| |
| 3) PLANS INDICATE THE USE OF FIRE |
| RETARDANT TREATED PLYWOOD AS BACKING FOR |
| THE EXPANDED METAL WIRE LATH. TABLE 601 |
| FOOTNOTE (C-2). |
| 2. IN TYPE I AND II CONSTRUCTION, |
| FIRE-RETARDANT-TREATED WOOD SHALL BE |
| ALLOWED IN BUILDINGS INCLUDING GIRDERS |
| AND TRUSSES AS PART OF THE ROOF |
| CONSTRUCTION WHEN THE BUILDING IS: |
| I. TWO STORIES OR LESS IN HEIGHT; |
| II. TYPE II CONSTRUCTION OVER TWO |
| STORIES; OR |
| III. TYPE I CONSTRUCTION OVER TWO |
| STORIES AND THE VERTICAL DISTANCE FROM |
| THE UPPER FLOOR TO THE ROOF IS 20 FEET |
| OR MORE. |
| THE ABOVE FOOTNOTE IS THE ONLY AREAS |
| THAT PLYWOOD COULD BE USED IN ROOF |
| CONSTRUCTION. |
| |
| 4) THE OTHER ISSUE WITH PLYWOOD IS |
| CONSIDERED SOLID BACKING AND FOR WIRE |
| LATH SPACED 1/4" OFF THE FACE OF THE |
| PLYWOOD TO ALLOW THE STUCCO TO KEY. SEE |
| ASTM C-1063.WE WILL NEED TO KNOW THE |
| WWEIGHT OF THE WIRE LATH TO BE USED, |
| WHAT TYPE OF FRAMING WIL BEUSED TO |
| SUPPORT THE WIRE LATH. |
| |
| 5) DISCREPANCY THE PERMIT APPLICATION |
| INDICATES ONLY 614 SQ FT OF BREEZEWAY IS |
| TO BE REPAIRED. WHEREAS THE PLANS IN THE |
| KEY PLAN 2,432 OF NEW CEILING AND 3,475 |
| OF NEW GROUND SURFACE ? PLEASE UPDATE |
| THE PERMIT APPLICATION AND VALUE OF |
| PROJECT OR THE CITY WILL USE MARSHAL & |
| SWIFT TO CALCULATE THE VALUE OF THE |
| PROJECT. |
| |
| 6) WILL THERE BE NEW ROOF DECKS |
| REQUIRING ROOFING PERMITS? |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| |
| |