Date |
Text |
2006-06-27 00:00:00 | |
| |
| 1) PROVIDE CLEAR AND DETAIL INSTRUCTIONS |
| FOR THE REMOVAL OF THE AWNINGS DURING |
| PERIODS OF 75MPH WINDS VELOCITY.OR THEY |
| SHALL BE DESIGN TO WITH-STAND WINDS OF |
| 140MPH. A NOTORIZE LETTER FROM THE OWNER |
| IS REQUIRED STATING THAT THE AWNINGS |
| WILL BE REMOVED OR REPOSITIONED DURING |
| PERIODS OF HIGH WINDS OF 75MPH. |
| |
| 2)3105.4.2.1 |
| THE WIND DESIGN LOADS FOR ANY FABRIC OR |
| MEMBRANE-COVERED STRUCTURE DESIGNED WITH |
| A QUICK REMOVAL OR BREAKAWAY MEMBRANE OR |
| FABRIC AT WIND VELOCITIES OF 75 MPH, |
| SHALL BE BASED ON THE FOLLOWING |
| CRITERIA: |
| 1. MINIMUM WIND VELOCITY OF 3-SECOND |
| WIND GUST 90 MPH |
| 2. IMPORTANCE FACTOR BASED ON LOW HAZARD |
| TO HUMAN LIFE OF 0.77. |
| 3. EXPOSURE CATEGORY B FOR OR C AS |
| DEFINED IN CHAPTER 16 . FOR MORE |
| INFORMATION SEE SEC. 3105 FBC. |
| |
| 3)2004 FL. BLD CODE 1603.1.4 THE |
| FOLLOWING INFORMATION RELATED TO WIND |
| SHALL BE SHOWN ON THE CONSTRUCTION |
| DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT, |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| )NOTE: PLANS REQUIRED TO BE SIGNED, |
| DATED AND SEALED BY THE ARCHITECT, |
| PLEASE SEE FS 481.221 AND FAC 61G1-16 |
| |
| |
| 4) ENGINEERS SHALL LEGIBLY INDICATE |
| THEIR NAME, ADDRESS AND LICENSE NUMBER |
| ON EACH SHEET. IF PRACTICING THROUGH A |
| DULY AUTHORIZED ENGINEERING BUSINESS, |
| ENGIN- EERS, ENGINEERS SHALL LEGIBLY |
| INDICATE THEIR NAME AND LICENSE NUMBER, |
| AS WELL AS, THE NAME, ADDRESS AND |
| CERTIFICATE OF AUTHORIZATION NUMBER OF |
| THE ENGINEERING BUSINESS ON EACH SHEET. |
| A TITLE BLOCK WILL SATISFY THIS |
| REQUIREMENT. FAC 61G15-23.002(2) - FS |
| 471.025 |
| |
| 5) FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT BEFORE A |
| PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OF |
| COMMENCEMENT IS NOT ACTUALLY COMMENCED |
| WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| TEL:(561)805-6726 |