2006-09-29 00:00:00 | ******REVISION DENIED****** |
| REFERENCE: FBC-2004 FUEL GAS |
| |
| THE FOLLOWING INFORMATION IS REQUIRED |
| FOR GAS PLAN REVIEW ON THE SUBMITTED |
| REVISION: |
| |
| 1. SUBMIT TWO COPIES OF A SITE SURVEY |
| PLAN INDICATING THE NEW PROPOSED |
| LOCATION OF THE GENERATOR WITH THE |
| INDICATION OF ALL DIMENSIONS FROM |
| PROPERTY LINES AND DISTANCES FROM |
| ADJACENT STRUCTURES. |
| 2. INDICATE ON THE SITE SURVEY PLAN THAT |
| THE NEW LOCATION GENERATOR EXHAUST ARE |
| NOT INSTALLED ANY CLOSER THAN TEN FEET |
| FROM ANY OPENING INTO THE DWELLING |
| STRUCTURE. THIS INCLUDES DOORS, WINDOWS, |
| AND ATTIC VENTILATION OPENINGS. |
| 3. SUBMIT TWO COPIES OF MANUFACTURER |
| INSTALLATION INSTRUCTIONS AND |
| MANUFAFTURER SPECIFICATIONS INDICATING |
| GENERATOR DIMENTIONS, BTU LOAD AND |
| INSTALLATIONCLEARENCES FROM ADJACENT |
| STRUCTURES. |
| 4. THE APPROVED GENERATOR FOR SAID |
| ADDRESS IS A 37KW NATURAL GAS GENERATOR |
| NOT A 38KW PLEASE CORRECT FOR |
| RESUBMITTAL. |
| 5. THE APPROVED GENERATOR BTU LOAD IS |
| 570,000 NOT 623,000 PLEASE CORRECT FOR |
| RESUBMITTAL. |
| 6. THE TOTAL BTU'S ARE INCORRECT ON THE |
| DRAWING. THE CORRECT TOTAL BTU'S SHOULD |
| BE 1,292,000 NOT 1,345,OOO PLEASE |
| CORRECT FOR RESUBMITTAL. |
| |
| END OF COMMENTS: |
| |
| REVIEW BY MIKE PERSON |
| (561) 805-6730 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |
| UNDER SUPERVISION OF K.STEVENS |
| (561) 805-6721 |
| |
| |