Plan Review Notes
Plan Review Notes For Permit 06041267
Permit Number 06041267
Review Stop P
Sequence Number 1
Notes
Date Text
2006-05-05 00:00:00DENIED;
 1.PAGE 8.2 ELEVATION #5 BREAK SINK TO
 COMPLY WITH FBC-2004 CHAPTER 11 SEC.
 11-4.23.3 KNEE CLEARANCE, 27"HIGH 30"
 WIDE AND 19" DEEP FOR FRONTAL APPROACH.
 11-4.24.6 RAP EXPOSED PIPES, 11-4.23.7
 LEVER OPERATED FAUCET REQUIRED. (SHOW
 DETAIL).
 2.SANITARY AND WATER ISOMETRIC DIAGRAMS
 SHOW P-9 SINKS IN ROOMS 104, 105, 107,
 AND 108. FLAT DRAWING SHOWS P-2.
 DISCRIPTION OF P-9 REQUIRED ON DRAWINGS.
 3.SHOW TOTAL OCCUPENCY FOR COMPLIANCE TO
 FBC-2004 PLUMBING TABLE 403.1(2B).
 4.A DRINKING FOUNTAIN IS REQUIRED. SHALL
 COMPLY WITH SECTION 410 AND
 ACCESSIBILITY CODE SEC. 11-4.1.3(10).
 SHOW DETAIL ON DRAWING.
 5.A WASTE AND VENT BRANCH IS REQUIRED
 FOR VACUUM EQUIPMENT SEC. 713.7.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  