 ******PROVISO******
 FUTURE GENERATOR GAS PIPING AT OWN RISK,
 SEPERATE GEN/RES PERMIT REQUIRED WITH
 ZONING APPROVAL OF GENERATOR PLACEMENT.
 NOTE: FUTURE GENERATOR AND POOL TO BE
 HARD (PRESSURE) CAPPED FOR FINAL GAS
 INSPECTION.
  
 IF 50,000 BTU WATER HEATER ROOM IS A
 CONFINED SPACE, OPENINGS REQUIRED PER
 SECTION 304.5 OR SECTION 304.6. SHALL BE
 INSTALLED.
 MINIMUM 2,500 CUBIC FEET REQUIRED.
  
 IF 180,000 BTU WATER HEATER ROOM IS A
 CONFINED SPACE, OPENINGS REQUIRED PER
 SECTION 304.5 OR SECTION 304.6 SHALL BE
 INSTALLED.
 MINIMUM 9,000 CUBIC FEET REQUIRED.