Plan Review Notes For Permit 06040569 |
Permit Number |
06040569 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2006-05-02 00:00:00 | BUILDING REVIEW SECOND CHECKLIST: | | 1- HIGHLIGHTED FLAT ROOF SYSTEMS (PAGES | | 31 AND 31 OF THE DADE COUNTY NOA | | #03-0827.02) ARE LIMITED BY GENERAL | | LIMITATION #9. THIS LIMITATION DOESN'T | | ALLOW CALCULATIONS FOR NAIL ENHANCING. | | THEREFORE IT CAN NOT BE USED. SELECTED | | SYSTEM MUST MEET OR EXCEED THE DESIGN | | PRESSURES OF TABLE R301.1(2) OF 2004 | | FLORIDA RESIDENTIAL CODE. | | | | 2- A) IF ANOTHER SYSTEM IS SELECTED AND | | LIMITED BY GENERAL LIMITATION #7, THEN | | PROVIDE SIGNED AND SEALED CALCULATIONS | | DONE BY ANY OF THE PROFESSIONALS LISTED | | IN GENERAL LIMITATION #7. | | B) QUALIFIER PERSON FOR RE ROOF | | AMERICA IS NOT A REGISTERED ROOF | | CONSULTANT. SEE GENERAL LIMITATION #7 | | TO SEE WHO IS QUALIFIED TO PROVIDE SUCH | | CALCULATIONS. | | C) SELECT ONLY ONE APPROVED ASSEMBLY. | | PULL OUT THE REST OF THE ASSEMBLIES FROM | | THE DADE COUNTY NOA. SEE CITY POLICY FOR | | RE-ROOF PERMITS AND REQUIREMENTS. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (5610805-6712 |
|