Date |
Text |
2006-05-15 00:00:00 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBCFLORIDA BUILDING CODE 2004 |
| FBC EBFLORIDA BUILDING CODE 2004 |
| EXISTING BUILDING CODE |
| FBC*CITY OF WEST PALM BEACH |
| AMENDMENTS TO THE FBC2004 |
| |
| 1.)A NOTICE OF COMMENCEMENT MUST BE |
| FILED WITH THE CLERK OF COURTS BEFORE A |
| PERMIT CAN BE ISSUED.THE NOC MUST |
| INCLUDE THE LEGAL DESCRIPTION, FS713.13. |
| |
| 2.)THE SITE PLAN SHOWS A PROPOSED |
| CHURCH, SURVEY SHOWS THE CHURCH AS |
| EXISTING.CLARIFY SCOPE OF WORK. |
| |
| 3.)SEE FBC11-4.1(1)(A).THIS SECTION |
| AFFECTS SOME OF THE COMMENTS BELOW. |
| |
| 4.)THE ACCESSIBLE PARKING DETAIL IS TO |
| COMPLY WITH CITY OF WEST PALM BEACH |
| STANDARDS, SEE ATTACHED. |
| |
| 5.)SHOW THE ACCESSIBLE ROUTE |
| FBC11-4.1.2(2).SHOW WIDTH AND SLOPE. |
| |
| 6.)SHOW THE ACCESSIBLE ENTRANCES. |
| COMPLIANCE WITH FBC11-4.6.2 CANNOT BE |
| DETERMINED WITHOUT THIS INFORMATION. |
| |
| 7.)PROVIDE WIDTH OF THE ACCESSIBLE |
| PARKING SPACES, FBC11-4.6.2. |
| |
| 8.)SEE FBC11-4.6.2(1), SHOW 44IN |
| ACCESSIBLE ROUTE. |
| |
| 9.)SEE FBC11-4.6.2(1), THE ACCESSIBLE |
| PARKING SPACE TO THE SOUTH, PASSENGER |
| MUST WALK BEHIND A PARKED CAR.REVISE. |
| |
| 10.)SHOW THE WIDTH OF THE PARKING |
| ACCESS AISLES AND SHOW HOW THEY CONNECT |
| TO AN ACCESSIBLE ROUTE, FBC11-4.6.3. |
| |
| 11.)SHOW MAX CROSS SLOPE OF PARKING |
| SPACES, FBC11-4.6.3. |
| |
| 12.)NO SIGNAGE IS SHOWN.SEE |
| FBC11-4.6.4 AND SHOW COMPLIANCE. |
| |
| 13.)SEE FS481.229.THIS IMPROVEMENT |
| INVOLVING ACCESSIBILITY DOES NOT FALL |
| UNDER ANY OF THE EXEMPTIONS TO |
| ARCHITECTURE. |
| |
| 14.)SEE FS471.003.IT IS NOT CLEAR |
| HOW THE STRUCTURAL ELEMENT OF THE 6? |
| HIGH BLOCK WALL IS EXEMPT FROM |
| PROFESSIONAL ENGINEERING. |
| |
| 15.)IRRIGATION AND DRAINAGE HAVE BEEN |
| CHECKED ON THE PERMIT APPLICATION, BUT |
| NO PLANS WERE PROVIDED.NOTE THAT NO |
| PLUMBING REVIEW HAS BEEN DONE AS NO |
| PLUMBING INFORMATION WAS PROVIDED. |
| SEPARATE PERMIT WITH SEPARATE PLANS |
| REQUIRED.PLEASE REMOVE FROM THE PERMIT |
| APPLICATION. |
| |
| 16.)PROVIDE WIND DESIGN CRITERIA |
| FBC1603.1.4. |