Plan Review Notes For Permit 06040017 |
Permit Number |
06040017 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2006-04-14 00:00:00 | NOTE: RESTAMP PLANS WITH PROVISO'S ADDED | | | | | | ******PROVISO****** | | 1) COMPLY WITH FBC-2004 SEC. 424.2 PRI- | | VATE SWIMMING POOLS. | | 2) FBC-2004 SEC. 424.2.6.1 ENGINEERING | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | ANSI/NSPI-5. | | 3) FBC-2004 SEC.424.2.6.6.5 WHERE | | PROVIDED, THE VACUUM OR PRESSURE CLEANER | | FITTING SHALL BE LOCATED AT LEAST 6" AND | | NOT GREATER THAN 12" BELOW THE MINIMUM | | OPER- ATING WATER LEVEL OR AS AN | | ATTACHMENT TO THE SKIMMER. | | 4) FBC-2004 SEC. 424.9 WATER SUPPLY, | | LOCAL ORD. #2853-95, BACKFLOW REQUIRED | | ON WATER SERVICE. | | 5) FBC-2004 SEC. 424.2.12.1 PRESSURE | | TESTS. PER MANUFACTURE RECOMMENDATIONS, | | NO AIR TEST SHALL BE APPROVED FOR PVC | | PIPE AND FITTINGS. | | 6) FBC-2004 SEC. 424.2.13.2 JOINTS AND | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPE. | | | | | | | | |
|