2006-05-08 00:00:00BUILDING PLAN REVIEW
 PERMIT:06030925
 ADD: 433 AVON RD
 CONT: BURCHANDT CONSTRUCTION
 TEL: (561)718-2602
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE
 ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUM- BER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICA TION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
  
 3) 109.3.10.1 HURICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM
 HIGHWINDS.
 ANY PERSONS WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
 4) WPB ADMIN105.9*
 FL S S 469. THIS AGENCY IS THE LOCAL
 ASBESTOS AUTHORITY, AND SHOULD RECEIVE
 ALL NOTIFICATIONS FOR BUILDING
 DEMOLITION OR RENOVATION PROJECTS.
 CONTACT THEM FOR GENERAL INFORMATION ON
 ASBESTOS ISSUES INCLUDING REGULATIONS,
 CONTRACTORS OR CONSULTANTS.FL SS 469.003
 PALM BEACH COUNTY PUBLIC HEALTH UNIT
 (DIVISION OF ENVIROMENTAL SCIENCE &
 ENGINEERING AIR POLLUTION CONTROL
 SECTION)
 901 EVERNIA STREET
 WEST PALM BEACH, FL 33401
 (561)366-3070
  
 5) SHEET A-1:
 5A) WEST ELEVATION, PROVIDE INFORMATION
 HOW CLOSE THIS BUILDING IS TO THE
 PROPERTY LINE? TABLE TABLE 602.
  
 5B) PLANS INDICATE A PROPOSED PAINT
 SPRAY BOOTH, PROVIDE DETAIL SHEETS.
  
 5C) PLANS INDICATE NEW WALLS ABOVE THE
 RESTROOMS, A EQUIPMENT PLATFORM. DETAIL#
 8 DOESN'T INDICATE IF THE METAL STUDS
 ARE DRYWALL OR STRUCTURAL RATED?
 ARE THE STAIRS GOING TO THE PLATFORM NEW
 ALSO? NO DETAILS?
 505.5 INDUSTRIAL EQUIPMENT PLATFORMS.
 INDUSTRIAL EQUIPMENT PLATFORMS IN
 BUILDINGS SHALL NOT BE CONSIDERED AS A
 PORTION OF THE FLOOR BELOW. SUCH
 EQUIPMENT PLATFORMS SHALL NOT CONTRIBUTE
 TO EITHER THE BUILDING AREA OR THE
 NUMBER OF STORIES AS REGULATED BY
 SECTION 503.1 . THE AREA OF THE
 INDUSTRIAL EQUIPMENT PLATFORM SHALL NOT
 BE INCLUDED IN DETERMINING THE FIRE
 AREA. INDUSTRIAL EQUIPMENT PLATFORMS
 SHALL NOT BE A PART OF ANY MEZZANINE,
 AND SUCH PLATFORMS AND THE WALKWAYS,
 STAIRS AND LADDERS PROVIDING ACCESS TO
 AN EQUIPMENT PLATFORM SHALL NOT SERVE AS
 A PART OF THE MEANS OF EGRESS FROM THE
 BUILDING.
  
 505.5.1 AREA LIMITATIONS.
 THE AGGREGATE AREA OF ALL INDUSTRIAL
 EQUIPMENT PLATFORMS WITHIN A ROOM SHALL
 NOT EXCEED TWO-THIRDS OF THE AREA OF THE
 ROOM IN WHICH THEY OCCUR. WHERE AN
 EQUIPMENT PLATFORM IS LOCATED IN THE
 SAME ROOM AS A MEZZANINE, THE AREA OF
 THE MEZZANINE SHALL BE DETERMINED BY
 SECTION 505.2 , AND THE COMBINED
 AGGREGATE AREA OF THE EQUIPMENT
 PLATFORMS AND MEZZANINES SHALL NOT
 EXCEED TWO-THIRDS OF THE ROOM IN WHICH
 THEY OCCUR.
  
 6) THE SOUTHEAST CORNER OF THE BUILDING
 A PLATFORM AND STAIRWAY ARE CONSTRUCTED,
 PROVIDE MORE DETAILS?
  
 7A)1609.1.4 PROTECTION OF OPENINGS.
 IN WIND-BORNE DEBRIS REGIONS, EXTERIOR
 GLAZING THAT RECEIVES POSITIVE PRESSURE
 IN THE LOWER 60 FEET (18.3 M) IN
 BUILDINGS SHALL BE ASSUMED TO BE
 OPENINGS AND THE BALANCE OF GLAZED
 OPENINGS IN THE REST OF THE BUILDING
 SHALL BE ASSUMED TO BE ZERO UNLESS SUCH
 GLAZING THAT RECEIVES POSITIVE PRESSURE
 IS IMPACT RESISTANT OR PROTECTED WITH AN
 IMPACT RESISTANT COVERING MEETING THE
 REQUIREMENTS OF SSTD 12, ASTM E 1886 AND
 ASTM E 1996, OR MIAMI-DADE TAS 201, 202
 AND 203 REFERENCED THEREIN AS FOLLOWS:
 1.GLAZED OPENINGS LOCATED WITHIN 30
 FEET (9.1 M) OF GRADE SHALL MEET THE
 REQUIREMENTS OF THE LARGE MISSILE TEST.
 2.GLAZED OPENINGS LOCATED MORE THAN
 30 FEET (9.1 M) ABOVE GRADE SHALL MEET
 THE PROVISIONS OF THE SMALL MISSILE
 TEST.
  
 7B) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 7C) WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 7D) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 1) WINDOWS
 2) MOTORIZED OVERHEAD DOORS
 3) STOREFRONT WINDOWS
 4) STOREFRONT DOORS
 5) MULLIONS
  
 8) PROVIDE INFORMATION ON COMPLIANCE
 WITH TABLE 302.1.1PAINT SHOP 2HR
 SEPERATION OR 1HR AND PROVIDE AUTOMATIC
 FIRE -EXTINGUISHING SYSTEM.
  
 9) PROVIDE THE AMOUNT OF PAINT AND
 SOLVENTS TO BE STORED ON SITE AND
 FLAMMIBLITY, THIS WILL DICTATE OCCUPANCY
 SEE CONTROL AREAS TABLE 307.7(1)
  
 10) PROVIDE MSDS SHEETS FOR THE ABOVE
 MATERIALS.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  