2006-04-13 00:00:00****CORRECTIONS****
 ****RAS 117 CALCULATIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)IT IS NOT CLEAR AS TO HOW YOU HAVE
 DETERMINED THE SQUARE FEET PER FASTENER,
 .667 IN THE FORMULA FOR FY TO ARRIVE AT
 THE FASTENER VALUE OF 40 LBF.SUBMIT
 CALCULATIONS IN ACCORDANCE WITH RAS 117,
 10.4.2.