Plan Review Notes For Permit 06020819 |
Permit Number |
06020819 |
|
Review Stop |
G |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2006-03-16 00:00:00 | PAUL SCHMITZ | | [email protected] | | FBC 2004 PLUMBING CODE PLAN REVIEW | | FBC2004 FUEL GAS CODEPLAN REVIEW | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | DENIED | | | | 1) GAS WATER HEATERS LOCATED IN CLOSETS | | IN EACH UNIT NOT APROVED. | | SECTION 303 APPLIANCE LOCATION | | 303.1 GENERAL. | | APPLIANCES SHALL BE LOCATED AS REQUIRED | | BY THIS SECTION, SPECIFIC REQUIREMENTS | | ELSEWHERE IN THIS CODE AND THE | | CONDITIONS OF THE EQUIPMENT AND | | APPLIANCE LISTING. | | 303.2 HAZARDOUS LOCATIONS. | | APPLIANCES SHALL NOT BE LOCATED IN A | | HAZARDOUS LOCATION UNLESS LISTED AND | | APPROVED FOR THE SPECIFIC INSTALLATION. | | 303.3 PROHIBITED LOCATIONS. | | APPLIANCES SHALL NOT BE LOCATED IN, OR | | OBTAIN COMBUSTION AIR FROM, ANY OF THE | | FOLLOWING ROOMS OR SPACES: | | 1. SLEEPING ROOMS. | | 2. BATHROOMS. | | 3. TOILET ROOMS. | | 4. STORAGE CLOSETS. | | 5. SURGICAL ROOMS. | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|