2006-02-10 00:00:00 | DENIED | | REFERENCE: FBC-2004 FUEL GAS | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR GAS PERMIT: | | | | 1. INDICATE ON THE DRAWING ALL CUT | | SECTIONS OF PIPE AND CORRESPONDING | | LENGTHS PER FBC-2004 FUEL GAS CODE. THE | | ONLY PIPE INDICATED ON DRAWING IS 45' OF | | 3/4" PE. DROPS AND RISERS LENGTHS AND | | TYPE OF MATERIAL BEING USED NEED TO BE | | INDICATED ON DRAWING. ALSO VALVES NEED | | TO BE INDICATED ON DRAWING, THERE NEEDS | | TO BE A SHUT OFF VALVE TO GENERATOR. | | 2. NEED SPECS ON GENERATOR, ORIGINAL | | GEN-RES PERMIT APPLICATION DENIED AND | | P/U. THEY NEED TO BE RESUBMITTED AND | | PASSED BY ZONING BEFORE GAS PERMIT CAN | | BE ISSUED. | | 3. LONGEST LENGTH: DRAWING INDICATES | | 45'. IS THIS THE LONGEST LENGTH ON | | SYSTEM? | | 4. TYPE OF GAS, (LP OR NATURAL) | | INDICATE ON DRAWING | | 5. TOTAL BTU LOAD ON SYSTEM NEEDS TO BE | | INDICATED ON DRAWING | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561)805-6730 | | FAX (561)805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561)805-5621 |
|