Plan Review Notes
Plan Review Notes For Permit 06011287
Permit Number 06011287
Review Stop B
Sequence Number 1
Notes
Date Text
2006-03-22 00:00:00 
  
 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 3) PLANS WERE SUBMITTED AFTER JAN.1,
 2004 AND AS SUCH THE ENGINEER'S SEAL
 WAS MANDATED TO CHANGE IN APPEARANCE PER
 61G15-23.001 FAC
  
 4) PROVIDE DRAWING OF EXISTING LAYOUT
 WITH AJOINING ROOMS FOR BETTER
 UNDERSTANDING OF ADDITION OR MOVING OF
 EXISTING STRUCTURE AND SYSTEMS SUCH AS
 PLUMBING, MECHANICAL AND ELEC.
  
 5) SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 CONFORM WITH R802.10.1 FBC
  
 6) DRAWING S/1 SPECIFIES REMOVAL OF WALL
 BELOW TIE BEAM, DOES PARALLAM BEAM
 REPLACE TIE BEAM? PLEASE CLARIFY
  
 7) DRAWING S/3 DETAIL 1 SHOWS TRUSS
 TAILS, WILL THEY BE REMOVED? ALSO IS
 TRIPLE JACK POST TO RUN ALLTHE WAY TO
 PARALLAM BEAM FOR BEARING WITHOUT DOUBLE
 TOP PLATE BECAUSE THERE IS NO WALL
 UNDERNEATH. CLARIFY ON DRAWINGS
  
 8) DRAWING S/2 SHOWS AN EXISTING BEAM TO
 REMAIN, IF BEAM IS IN CEILING WHAT IS
 RELATIONSHIP TO NEW TRUSS GIRDER AND
 ATTACHMENT TO NEW PARALLAM BEAM?
  
 9) ELEVATION DRAWING SHALL PROVIDE
 FIN.FL. EL, BEAM EL, AND MEAN ROOF HT.
  
 10) SUBMIT SOIL REPORT, MAY USE COPY OF
 EXISTING PER
  
 11) SUBMIT A SOIL REPORT PER 1802.1-
 1802.2.2 FBC
  
 12) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
  
 IS RELEVANT. THESE SHOULD INCLUDE THE
 FLORIDA STATE APPROVAL COVER PAGES, AND
 THE PRODUCT NOA THAT LISTS THE SYSTEM
 COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM
 TO BE USED AND THE GENERAL LIMITATIONS
 PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORG
  
 13) PLEASE SEE JELD-WEN DOORS (THE FIRST
 4 PAGES IS THE STATE APPROVAL COVER
 SHEETS). THESE ARE REQUIRED FOR THE
 SHINGLES ALONG WITH THE UPDATED NOA, THE
 STORM PANELS AND WINDOWS ARE OK AS IS
  
 14) PROVIDE PRODUCT APPROVAL FOR FLAT
 AREA OF THE ROOF AS SHINGLES ARE NOT
 PERMITTED ON ROOF SLOPES LESS THAN 2/12
  
 15) THOSE PRODUCTS WHICH ARE REGULATED
 BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 WPB
 AMENDMENTS TO FBC 2004
  
 16) STRUCTURAL NOTES ON S/3 UPDATE NOTES
 TO 2004. WIND LOADS ARE NOW 1609
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH
 ADMINISTATIVE AMMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
  
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy