2006-03-22 00:00:00 | |
| |
| DENIED |
| |
| 1)BEFORE A PERMIT TO CONSTRUCT, MAY |
| BE ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE ACTUAL PERMIT |
| SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 2) THE CLAIMED VALUATION ON THE PERMIT |
| APPLICATION IS LOW. FOR PERMITTING |
| PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT |
| COST EXCLUDING LAND VALUE. OUR VALUATION |
| REFERENCE IS ICC (BVD), MARSHALL-SWIFT |
| AND MEANS COST ANALYSIS SERVICES PER |
| 108.3 FBC* |
| |
| 3) PLANS WERE SUBMITTED AFTER JAN.1, |
| 2004 AND AS SUCH THE ENGINEER'S SEAL |
| WAS MANDATED TO CHANGE IN APPEARANCE PER |
| 61G15-23.001 FAC |
| |
| 4) PROVIDE DRAWING OF EXISTING LAYOUT |
| WITH AJOINING ROOMS FOR BETTER |
| UNDERSTANDING OF ADDITION OR MOVING OF |
| EXISTING STRUCTURE AND SYSTEMS SUCH AS |
| PLUMBING, MECHANICAL AND ELEC. |
| |
| 5) SUBMIT ENGINEERED TRUSS DRAWINGS THAT |
| CONFORM WITH R802.10.1 FBC |
| |
| 6) DRAWING S/1 SPECIFIES REMOVAL OF WALL |
| BELOW TIE BEAM, DOES PARALLAM BEAM |
| REPLACE TIE BEAM? PLEASE CLARIFY |
| |
| 7) DRAWING S/3 DETAIL 1 SHOWS TRUSS |
| TAILS, WILL THEY BE REMOVED? ALSO IS |
| TRIPLE JACK POST TO RUN ALLTHE WAY TO |
| PARALLAM BEAM FOR BEARING WITHOUT DOUBLE |
| TOP PLATE BECAUSE THERE IS NO WALL |
| UNDERNEATH. CLARIFY ON DRAWINGS |
| |
| 8) DRAWING S/2 SHOWS AN EXISTING BEAM TO |
| REMAIN, IF BEAM IS IN CEILING WHAT IS |
| RELATIONSHIP TO NEW TRUSS GIRDER AND |
| ATTACHMENT TO NEW PARALLAM BEAM? |
| |
| 9) ELEVATION DRAWING SHALL PROVIDE |
| FIN.FL. EL, BEAM EL, AND MEAN ROOF HT. |
| |
| 10) SUBMIT SOIL REPORT, MAY USE COPY OF |
| EXISTING PER |
| |
| 11) SUBMIT A SOIL REPORT PER 1802.1- |
| 1802.2.2 FBC |
| |
| 12) THE PERMIT APPLICATION SHALL INCLUDE |
| TWO COPIES OF EACH PRODUCT APPROVAL THAT |
| |
| IS RELEVANT. THESE SHOULD INCLUDE THE |
| FLORIDA STATE APPROVAL COVER PAGES, AND |
| THE PRODUCT NOA THAT LISTS THE SYSTEM |
| COMPONENTS/ FASTENER LIST PAGES, THE |
| PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM |
| TO BE USED AND THE GENERAL LIMITATIONS |
| PAGE. ALL CAN BE FOUND ON |
| WWW.FLORIDABUILDING.ORG |
| |
| 13) PLEASE SEE JELD-WEN DOORS (THE FIRST |
| 4 PAGES IS THE STATE APPROVAL COVER |
| SHEETS). THESE ARE REQUIRED FOR THE |
| SHINGLES ALONG WITH THE UPDATED NOA, THE |
| STORM PANELS AND WINDOWS ARE OK AS IS |
| |
| 14) PROVIDE PRODUCT APPROVAL FOR FLAT |
| AREA OF THE ROOF AS SHINGLES ARE NOT |
| PERMITTED ON ROOF SLOPES LESS THAN 2/12 |
| |
| 15) THOSE PRODUCTS WHICH ARE REGULATED |
| BY DCA RULE 9B-72 SHALL BE REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL PER 106.3.3 WPB |
| AMENDMENTS TO FBC 2004 |
| |
| 16) STRUCTURAL NOTES ON S/3 UPDATE NOTES |
| TO 2004. WIND LOADS ARE NOW 1609 |
| |
| NOTE: FBC = FLORIDA BUILDING CODE 2004 |
| FBC* = WEST PALM BEACH |
| ADMINISTATIVE AMMENDMENTS TO FBC |
| FAC = FLORIDA ADMINISTRATIVE CODE |
| |
| |
| |
| BLDG PLAN REVIEW |