2006-06-15 00:00:00 | PERMIT: 06011130 |
| ADD: 2037 SPRUCE AVE |
| CONT:PLAN REVIEW |
| "WEST PALM BEACH HOUSING |
| AUTHORITY" |
| TEL: (561)655-8530 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2ND REVIEW |
| ACTION: DENIED |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 1) COMMENET# 6 FROM THE PREVIOUS REVIEW, |
| WPB ADMIN CODE 106.3* PRODUCT APPROVALS. |
| THOSE PRODUCT WHICH ARE REGULATED BY DCA |
| RULE 9B-72 SHALL BE REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| |
| 2)COMMENT# 12 FROM THE PREVIOUS REVIEW, |
| REPORT IS A COPY NOT RAISED SEAL. FL BLD |
| CODE 1804.2.2 QUESTIONABLE SOILS, WHERE |
| THE BEARING CAPACITY IS |
| NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| WHERE THE BEARING CAPACITY OF THE SOIL |
| IS NOT DEFINITLY KNOWN OR IS IN QUESTION |
| THE BUILDING OFFICIAL MAY REQUIRE EXPLOR |
| ATIONS, TEST OR OTHER ADEQUATE PROOF AS |
| TO THE PERMISSIBLE SAFE BEARING |
| CAPACITY. REQUIRED TEST AND RECOMMENDA- |
| TIONS SUBMITTED TO VERIFY BEARING CAPA- |
| CITY SHALL BE CERTIFIED BY A GEOTECH- |
| NICALREPORT FROM A DESIGN PROFESSIONAL |
| PROPERLY LICENSED IN THE STATE OF |
| FLORIDA. |
| |
| 3) COMMENT# 16 FROM THE PREVIOUS REVIEW, |
| FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A) TRUSS ANCHORS |
| B) ROOF ASSEMBLIES |
| C) STORM SHUTTERS |
| ROOF ASSEMBLIES, HIGHLIGHT WHICH |
| SUBSYSTEM THAT WILL BE USED, ALSO SEE IF |
| REPORT WILL REQUIRE ENHANCED FASTENING |
| LIMITATION# 7 OR 9. |
| |
| INDICATE WHERE STORM SHUTTERS WILL BE |
| STORED? |
| FL BLD CODE 2001 SECTION 103.6, |
| 1606.1.4, 1707.4 & 3401.7.2.4. |
| PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| SCHEDULE SUMMARIZING & IDENTIFYING |
| OPENING SIZES, STORY HEIGHTS, UNIT MARK |
| NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM |
| BAR REINFORCING REQUIREMENTS, WALL PRES- |
| SURE ZONES, SLAT TYPES, ETC., SHALL BE |
| SUBMITTED AT TIME OF PERMIT APPLICATION |
| TO FACILITATE PLAN REVIEW AND PERMIT |
| ISSUANCE. |
| PROVIDE STORM PANEL INFORMATION WITH |
| INSTALLATION SCHEDULE AND KEY PLAN WITH |
| SPECIFIC ANCHORS AND MOUNTING TO BE USED |
| FOR ALL NON-IMPACT GLAZING. |
| FBC 1606.1.4. |
| |
| 4) COMMENT# 18 FROM THE LAST REVIEW, |
| A200 & A500 DOOR WAY ND01 PLANS INDICATE |
| THE USE OF (2) 2'-8" DOORS. SEE |
| 11-4.13.5 A MINIMUM OF 32" CLEAR WIDTH |
| REQUIRED. |
| |
| 5) A401 & S204 COMMENT# 30 FROM THE |
| PREVIOUS REVIEW, PLANS INDICATE A |
| CONCRETE DECK, PROVIDE STEEL SIZE AND |
| LAYOUT FOR THE 2ND FLOOR CONCRETE DECK. |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| |
| |