Date |
Text |
2006-05-01 00:00:00 | DENIED |
| |
| |
| 1. 713.13 F.S.A NOTICE OF COMMENCEMENT |
| SHALL BE RECORDED AT PALM BEACH COUNTY |
| COURTHOUSE AND A COPY SUBMITTED TO THIS |
| OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| BLANK FORMS ARE AVAILABLE FROM THIS |
| OFFICE. |
| NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| 90 DAYS OF RECORDING. |
| |
| 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY. THE ACTUAL PERMIT |
| SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 3.SHOW GUARD RAIL DETAILS COMPLYING |
| WITH FBC 2004 1012.3 AND 1607.7 FOR |
| BALCONYS. |
| |
| 4.SUBMIT TWO COPIES OF ENERGY CALCS |
| PER 2004 FBC. |
| |
| 5.PRODUCT APPROVALS REQUIRED FOR |
| LINTELS, FLAT ROOF, ROOF TILE, STRAPS |
| AND TIE-DOWNS, EXTERIOR DOORS, WINDOWS, |
| IMPACT PROTECTION AND STORE FRONT |
| SYSTEM. |
| |
| 6.ALL PRODUCT APPROVALS SUBMITTED WITH |
| QUALITY ASSURANCE SHALL HAVE THE |
| FOLLOWING STATE APPROVAL ATTACHED. |
| PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A STATE PRODUCT APPROVAL |
| SHEETS THAT LISTS THE PRODUCT IDENTITY |
| NUMBER FROM THE STATE. IF THE PRODUCT |
| DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT |
| AN APPLICATION FOR LOCAL PRODUCT |
| APPROVAL OR SITE SPECIFIC FORM PER RULE |
| 9B-72. SEE ATTACHMENT. |
| WWW.FLORIDABUILDING.ORG |
| |
| 7.THOSE PRODUCT APPROVALS WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL.WPB |
| AMENDMENT TO FBC 106.3.3. |
| |
| 8.SUBMIT TWO SETS OF TRUSS DRAWINGS |
| FOR REVIEW PER 2004 FBC. |
| |
| 9.SUBMIT A LIFE SAFTEY PLAN. |
| |
| 10.BUILDING IS IN FLOOD ZONE "A". |
| SUBMIT A SOILS REPORT INCLUDING |
| RECOMMENDATIONS FOR FOOTINGS DESIGN. |
| |
| 11. MINIMUM PLAN REVIEW CRITERIA FOR |
| BUILDINGS.FBC 106.3.3 WPB AMMENDMENTS |
| |
| -CONSTRUCTION TYPE PER TABLE 503. |
| -OCCUPANCY GROUP |
| -OCCUPANCY LOAD |
| -SQUARE FOOTAGE FOR ALL AREAS FOR |
| EXAMPLE, BUSINESS, PARKING GARAGE, |
| STORAGE AREAS. |
| -INTERIOR FINISHES |
| |
| 12.SUBMIT INTERIOR FLOOR PLANS |
| INCLUDING SEPERATION OF AREAS. |
| |
| 13.EXISTING BUILDING ON PROPERTIES. |
| WILL THEY BE DEMOLISHED UNDER A SEPERATE |
| PERMIT? |
| |
| 14.SUBMIT AN APPROVED UNITY OF TITLE |
| FOR THE FOLLOWING PARCELS. |
| 74434315190070021 AND |
| 74434315190070010 |
| |
| 15.SUITE 101 SUBMIT DETAILS FOR |
| ADMISSION AREA SHOWING COMPLIANCE WITH |
| FBC 11-7. |
| |
| 16.ACCESSABLE PARKING SPACES MISSING |
| AND NOT SHOWN AT ALL LEVELS.SHOW CLEAR |
| PATH OF TRAVEL FROM PARKING TO BUILDING |
| ENTRANCE. |
| |
| 17. A-7 WEST ELEVATION; DOES NOT REFLECT |
| GROUND FLOOR PLAN. SOUTH STAIRS NOT |
| SHOWN, EXIT NOT SHOWN. |
| |
| 18.A-7 EAST ELEVATION; WHAT IS "L" NOT |
| SHOWN ON 3RD FLOOR |
| |
| 19.A-8.1 STAIR DETAIL, DOOR NOT SHOWN. |
| |
| 20. ROOF FRAMING IS ON GROUND FLOOR |
| FRAMING PAGE. |
| |
| 21.SHOW HOW ELEVATORS WILL COMPLY FOR |
| ACCESSABLILITY PER FBC 11-4.10 |
| |
| 22.SHOW CLEAR HEIGHT OF PARKING GARAGE |
| FBC 406.2.2 |
| |
| 23. OPEN PARKING GARAGE SHALL BE OF TYPE |
| I, II OR IV CONSTRUCTION. |
| |
| 24.HANDICAP PARKING SPACES SHALL BE IN |
| CLOSE PROXIMATY TO THE ELEVATOR. |
| |
| 25.MONUMENTAL STAIRS SHALL HAVE AN |
| INTERMEDIATE HANDRAIL.FBC 1009.11.2 |
| |
| |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. SUBMIT ONE COPY OF |
| OLD PAGES FOR REFERENCE. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET |
| OR SPECIFICATION PAGE WHERE THE CHANGES |
| CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| ART LANGE |
| CONSTRUCTION SERVICES DEPARTMENT |
| BUILDING PLANS EXAMINER |
| 561-805-6672 |