2006-04-10 00:00:00 | 1) NEED PRODUCT APPROVAL FOR NEW INPACT |
| GLASS DOOR.106.3.3* PRODUCT APPROVALS- |
| 2004 THOSE PRODUCTS THAT ARE RGULATED BY |
| DCA RULE 9B-72 SHALL BE REVIEWED AND |
| APPROVED IN WRITTING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL.TWO COPIES WITH |
| THE STATE COVER SHEETS REQUIRED. |
| |
| 2) ALL AWNINGS SHALL BE DESIGNED SO THAT |
| FABRIC OR MEMBRANE COVER CAN BE QUICKLY |
| AND EASILY REMOVED PER 3105.4.2.1 |
| TIGHTLY WRAPED OR WOVEN CORDS ARE NOT |
| ACCEPTABLE. PLEASE SUBMIT A DETAIL |
| DRAWING OF COBER ATTATCHMENT METHOD. |
| |
| 3) 11-4.13.6 MANEUVERING CLEARANCES AT |
| DOORS. |
| MINIMUM MANEUVERING CLEARANCES AT DOORS |
| THAT ARE NOT AUTOMATIC ORPOWER-ASSISTED |
| SHALL BE AS SHOWN IN FIGURE 11-25 . THE |
| FLOOR OR GROUND AREA WITHIN THE REQUIRED |
| CLEARANCES SHALL BE LEVEL AND CLEAR. SEE |
| FIG.25 (A). |
| |
| 4) 11-4.1.6(2) DUTY TO PROVIDE AN |
| ACCESSIBLE PATH OF TRAVEL TO ALTERED |
| AREAS SHALL BE DEEMED DISPROPORTIONATE |
| TO THE OVERALL ALTERATION WHEN THE COST |
| EXCEEDS 20 % OF THE COST OF THE ALTERA- |
| TION TO THE PRIMARY FUNCTION AREA. |
| (A)(I) AN ACCESSIBLE ENTRANCE |
| (II) AN ACCESSIBLE ROUTE |
| (III) AT LEAST ONE ACCESSIBLE REST- |
| ROOM FOR EACH SEX OR A SINGLE |
| UNISEX RESTROOM |
| (IIII) ACCESSIBLE TELEPHONE |
| (IV) ELEMENTS SUCH AS PARKING, STOR- |
| AGE OR ALARMS. SEE INFORMATION ON |
| PARKING SPACE IN PACKAGE. |
| |
| 5) THE ENERGY EFFICIENCY CODE FORMS ARE |
| REFERENCING THE 2001 CODE. HOWEVEER ALL |
| APPLICATIONS SUBMITTED AFTER OCTOBER 1ST |
| SHALL REFER TO THE 2004 FBC. |
| SEE 13-4000.0.A FOR MORE INFORMATION. |
| |
| 6) THE BOARD AMENDED ITS SEALS RULE |
| EFFECTIVE FEBRUARY 5TH, 2004, TO ALLOW |
| ENBOSSING SEALS MADE OF MATERIALS OTHER |
| THAN METAL AND AT THE SAME TIME CLEANED |
| UP THE APPERANCE OF THE SEAL BY |
| ELIMINATING OBSOLETE CONTENT AND |
| CHANGING THE WORD "CERTIFICATE" TO |
| "LICENSE". 61G15-23.001(1),F.A.C. |
| SEE MORE INFORMATION IN PACKAGE. |
| |
| 7) THE APPLICATION DOES NOT MENTION A |
| FOUNTAIN. WILL THE FOUNTAIN BE DONE ON A |
| SEPERATE PERMIT? IF SO SUBMIT PLANS WITH |
| ALL REQUIRED INFORMATION AND DETAILS ON |
| THE FOUNTAIN. |
| |
| 8) 110.2* W. P. B. ADMINISTRATIVE CODE, |
| INFORMATION THAT IS REQUIRED FOR RECORD |
| KEEPING & FOR CERTIFICATE OF OCCUPANCY: |
| A) THE EDITION OFTHE CODE UNDER WHICH |
| THE PERMIT WAS ISSUED. |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| WITH THE PROVISIONS OF CHAPTER 3. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED |
| IN CHAPTER 6, TABLE 601. |
| D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| IS REQUIRED. |
| F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| OF THE BUILDING PERMIT. |
| |