Plan Review Notes
Plan Review Notes For Permit 06010683
Permit Number 06010683
Review Stop B
Sequence Number 1
Notes
Date Text
2006-02-09 00:00:001) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE. NOTE: THE NOTICE OF COMMENCEMENT
 MUST BE RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT OR CONSTRUCTION IS NOT
 COMMENCED WITHIN 90 DAYS OF RECORDING.
  
 2) THERE IS NO GARAGE DOOR ON THIS
 STRUCTURE SO,WHY IS IT CALL A
 GARAGE/STUDIO? IF THE STRUCTURE WILL NOT
 BE USED AS A GARAGE, CHANGE THE
 DESCRIPTION ON THE APPLICATION TO MATCH
 THE USE AND OCCUPANCY OF THE BUILDING.
  
 3) PRODUCT APPROVALS WITH THE STATE
 COVER SHEET AND FL# ARE NEEDED FOR EACH
 PRODUCT INCLUDING THE ROOFING
 MATERIALS/DOORS AND WINDOWS/LINTELS ETC.
 THOSE PRODUCTS WHICH ARE GEGULATED BY
 DCA RULE 9B72 SHALL BE REVIEW AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 (W.P.B.AMENDMENTS) 106.3.3
  
 4) THE LUS28 SIMPSON HANGER IS TOO SHORT
 TO ACCOMIDATE A 2X12. I SUGGEST THAT YOU
 SPEAK WITH SIMPSON STRONG TIE AND GET
 THEIR ADVISE AS TO WHICH HANGE SHOULD BE
 USED.
  
 5) 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.CONSTRUCTION DOCUMENTS SHALL
 BE DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE
 BUILDING OFFICIAL (SEE ALSO SECTION
 106.3.5).
  
 6) 106.1.1.2 FOR ROOF ASSEMBLIES
 REQUIRED BY THE CODE, THE CONSTRUCTION
 DOCUMENTS SHALL ILLUSTRATE, DESCRIBE,
 AND DELINEATE THE TYPE OF ROOFING
 SYSTEM, MATERIALS, FASTENING
 REQUIREMENTS, FLASHING REQUIREMENTS AND
 WIND RESISTANCE RATING THAT ARE REQUIRED
 TO BE INSTALLED.PRODUCT EVALUATION AND
 INSTALLATION SHALL INDICATE COMPLIANCE
 WITH THE WIND CRITERIA REQUIRED FOR THE
 SPECIFIC SITE OR A STATEMENT BY AN
 ARCHITECT OR ENGINEER FOR THE SPECIFIC
 SITE MUST BE SUBMITTED WITH THE
 CONSTRUCTION DOCUMENTS.ALSO SEE ROOFING
 PROCEDURE IN PACKAGE.
  
 7) NOTE: THE WIND LOAD SECTION IN THE
 FBC IS 1609 NOT 1606. CHANGE NOTES TO
 REFLECT THE CORRECT SECTION.
  
 8)A SITE PLAN IS REQUIRED SHOWING THE
 EXACT OUTLINE,SIZE AND LOCATION OF
 PROPOSED ADDITION AND EXISTING BUILDINGS
 AND SHOW DISTANCE TO PROPERTY LINES.ETC.
 SITE DRAWINGS. DRAWINGS SHALL SHOW THE
 LOCATION OF ALL NEW WORK, INCLUDING THE
 PROPOSED BUILDING OR STRUCTURE, AND OF
 ALL EXISTING MAN-MADE IMPROVEMENTS AND
 EVERY EXISTING SURVEY, OR OTHER SPECIAL
 SURVEY, PREPARED BY A QUALIFIED
 SURVEYOR. IF REQUIRED, SURVEYS SHALL BE
 PREPARED IN ACCORDANCE WITH PROVISIONS
 OF CHAPTERS 177 AND 472 FLORIDA
 STATUTES, AND RULE 61G17, FLORIDA
 ADMINISTRATIVE CODE. (W.P.B AMENDMENTS
 SEC.106.3.4)
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  
  
  
  